6. Trouble Shooting

Before using the product, please be sure that Power LED is on. If the Power LED is not on, please

check the following steps:

1. Check if the mains is normal.

2. Check if the power cord is connected firmly.

3. Check if the connected devices are connected to the unit firmly.

4. Check if the unit is turned on.

Problem

Possible Cause

Solutions

Circuit breaker is

“tripped”.

The unit is overload.

Remove some loads first. Reset the circuit

breaker by pressing the button again.

The unit is turned off

automatically and the

Power LED is not lit.

The unit is over-heated. It’s

internal protected function.

Remove some loads and wait until the unit

is cool. Then turn on the unit again.

7. Specifications

Model

AVR 600

AVR 1000

AVR 1200

CAPACITY

600VA / 360W

1000VA / 600W

1200VA / 720W

Input Voltage

220VAC

Input Voltage Range

180 - 264VAC

Input Frequency

50Hz

Voltage Regulation

+/-12%

Output AVR

+/-8%

INDICATOR
Power LED

Green lighting

Boost/Buck LED

Red lighting

PROTECTION

Comprehensive
Protection

Short circuit, overload, and over-temperature protection

PHYSICAL
Dimension (DxWxH)

166mm x 161mm x 86.7mm

Net Weight (kgs)

1.7

2.0

2.1

Environment
Humidity

0-90% RH @ 0-40° C (non-condensing)

Noise Level

Less than 40dB