Peerless-AV DCT100 - Installation User Manual

Page 2

Advertising
background image

ISSUED: 04-24-00 SHEET #: 142-9002-4 04-21-05

Visit the Peerless Web Site at www.peerlessindustries.com

For customer service call 1-800-729-0307 or 708-865-8870.

2 of 2

Attach the adjustable extention column
according to the instructions provided with it.
Use a level to make sure the column is
plumb and make adjustments as necessary.

Tighten the hex bolts (E) to a maximum of
25 lbf

·

ft (34 N

·

m) so that the lock washers

(D) become flat. Mount your bracket
according to the instructions provided with it.

Note: Insert the M5 x 10 mm screw (F) into the
threaded pipe fitting as directed in the extension
column instructions. If you are using an extension
pipe without a notch, drill a 11/64" diameter through
the pipe and insert the screw through the decoupler
assembly (A) into the pipe; see Detail 2.

A

F

Detail 2

E

D

Advertising