Peerless-AV CMJ490 - Installation User Manual

Warning

Advertising
background image

ISSUED: 05-22-00 SHEET #: 128-9002-7 06-22-12

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112.

1 of 2

Installation Wood Joist Finished Ceiling,
Exposed Wood Joists, or Wood Beam Ceiling.
(See 3 for concrete ceilings). Drill four 5/32" (4 mm)
dia. holes to a minimum depth of 2.5" (64 mm).
Attach with four #14 x 2.5" (6 mm x 65 mm) wood
screws as shown using 3/8" (10 mm) socket
wrench. Tighten wood screws so ceiling plate is
firmly attached.

PARTS LIST

PART #

QTY.

DESCRIPTION

128-1039

1

ceiling plate (CMJ 470 only)

128-1086

1

ceiling plate (CMJ 480 only)

128-1087

1

ceiling plate (CMJ 490 only)

5S1-015-C03

4

#14 x 2.5" (6 mm x 65 mm) wood screw

2PT-22CA01D

2

end cap

520-9250

1

M5 x .8 x 10 mm phillips screw (for use
with extension column if applicable)

flush mount tube
(included with Jumbo
Mount Bracket)

ceiling
plate

From the top thread the Flush Mount Tube (included
with your Jumbo Mount Bracket) through the
threaded fitting in the ceiling plate.

Note: If you will install an extension column DO NOT
INSTALL THE FLUSH MOUNT TUBE. Begin with step 2.

Note: Read entire instruction sheet before
beginning installation and assembly.

Installation and Assembly - Ceiling Plate for Jumbo Mounts

Models: CMJ 470
CMJ 480 CMJ 490

Note: This ceiling plate is intended for use only to support Jumbo Mount TV Brackets or other products as specified by Peerless
Industries, Inc. Combine only as specified (see specifications on page 2). Fasteners provided are for attachment to wood struc-
tural members (joists or beam). Order additional fastener kit ACC 244 if attaching to a solid concrete ceiling. This product is
intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.

CEILING CONSTRUCTION

ADDITIONAL HARDWARE REQUIRED

Wood Joist, Wood Beam

none

Concrete

Concrete Anchor Kit - order accessory kit ACC 244.

Other or unsure?

Call Peerless Customer Care.

IMPORTANT!

Certain ceilings require additional mounting hardware...

For customer care, or to order
accessory kits call
1-800-7865-2112

Max. Load Capacity:

300 lb (137 kg)

end
cap

R

This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.

• Tighten wood screws so that ceiling plate is firmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the

center of the joists. The use of an "edge to edge" stud
finder is highly recommended.

WARNING

Advertising