Place projector mount assembly (A) on ceiling as a
template and mark the center of the two mounting
holes. Drill two 5/16" (8 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach projector mount assembly
(A) using two concrete anchors (W), two fl at washers
(I), and two #14 x 2.5" wood screws (V) as shown.

NOTE: Mounting slots on projector mount assembly
allow for 30° (±15°) of swivel adjustment before fully
securing wood screw.

Tighten wood screws (V) using 3/8" (10 mm) socket
wrench, phillips screwdriver until projector mount
assembly (A) is fi rmly attached.

Skip to step 6

Installation to Concrete Ceilings

3

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

WARNING

• Tighten wood screws fi rmly, but do not overtighten.

Overtightening can damage screws, greatly reducing
their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Always attach concrete anchors directly to load-

bearing concrete.

• Never attach concrete anchors to concrete covered

with plaster, drywall, or other fi nishing material. If
mounting to concrete surfaces covered with a fi nish-
ing surface is unavoidable, the fi nishing surface
must be counterbored as shown below. Be sure con-
crete anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8", custom fasteners must be supplied by installer.

WARNING

FRONT OF
MOUNT

W

V

I

A

1

3

2

W

Drill holes and insert anchors (W).

Place plate (A) over anchors (W) and secure with screws (V).

Tighten all fasteners.

A

W

V

I

concrete
surface

CUT

A

W

A

Y

VIEW

INCORRECT

CORRECT

plaster/
dry wall

plaster/
dry wall

concrete

concrete