Peerless-AV ACC120 - Installation User Manual

Warning, Installation and assembly - internal joist mount

Advertising
background image

Installation and Assembly - Internal Joist Mount

Model: ACC 120

1 of 2

IMPORTANT!

Read entire instruction sheet

before beginning installation and assembly.

E

B

C

D

F

G

Assemble as shown.

IMPORTANT: If installer is working above the
ceiling, such as in an attic space, assemble
exactly as pictured. If installer is working below
the ceiling, reverse positions of carriage bolts (F)
and nylock nuts (E).

Tighten 1/4-20 nylock nuts (E) just enough to
allow for expansion / compression of extension
brackets (C & D).

D

A

E

B

C

F

G

PARTS LIST

PART #

QTY.

DESCRIPTION

A 500-9006

6

#10 x 3/4" phillips screw

B 092-1005

1

upper clamping bracket

C 092-1001

1

extension bracket - left

D 092-1001

1

extension bracket - right

E 530-9413

4

1/4-20 nylock nut

F 520-9556

4

1/4-20 x 3.75" carriage bolt

G 092-1007

1

lower clamping bracket

H 520-9250

1

M5 x .8 x 10 mm phillips screw
(for use with EXT models)

Parts may appear slightly different than illustrated.

Check parts list to ensure that
all parts have been included.

MAXIMUM LOAD CAPACITY: 300 lb (137 kg)
Maximum Load capacity refers to the combined
load of all attached equipment and hardware.

• Installer must verify that the ceiling will safely support

four times the combined weight of all attached equip-
ment and hardware.

WARNING

ISSUED: 6-12-97 SHEET #: 092-9001-3 08-24-12

Advertising