Warning, Cl or m k o, L or m o – Peerless-AV PLCK-UNL - Installation User Manual

Page 3

Advertising
background image

ISSUED:02-22-07 SHEET #: 202-9197-5 (2013-10-01)

Visit the Peerless Web Site at www.peerless-av.com

For customer care call 708-865-2112.

3 of 9

• For TV mounts: If equipment weighs over 50 lb, and

the extension exceeds 12’, a Stress Decoupler (mod-
els DCT 100/DCS 200) must be used in combination
with EXT extension columns.

WARNING

Attaching Extension Column To Ceiling Plate Or Existing Extension Column

Attach extension column (C) to column connector (K) or ceiling plate (not supplied). Align slot in the extension
column with one of the small holes in extension column connector (K) or existing retaining collar (not supplied).
Insert and tighten one phillips screw (L) through connector (K) or existing retaining collar into slot on the extension
column.

Note: For security option, use security screw (M) in place of screw (L). Tighten security screw (M) using 4 mm
security allen wrench (N)

Repeat step one to attach column connector (K) to existing extension column (not supplied).

Note: To prevent columns from unwinding when mount is swiveled, both screws (L) or (M) must be inserted.

Note: Slotted set screws (O) are used to jam against the threads of each connecting joint to prevent any excess
movement. Do not overtighten screws; overtightening screws will damage threads making it diffi cult to separate the
products.

1

slot

extension column

(not supplied)

slot

C

L or M

K

O

Attaching to Existing Extension Column

L or M

O

Attaching to Ceiling Plate

Small
Hole

Slot

Ceiling plate

(not supplied)

C

retaining

collar

Advertising