Warning – Peerless-AV ACC556 - Installation User Manual

Page 2

Advertising
background image

2 of 3

ISSUED: 01-11-93 SHEET #: 128-9007-2 11-16-04

Visit the Peerless Web Site at www.peerlessindustries.com

For customer service call 1-800-729-0307 or 708-865-8870.

wall

ceiling

A

For Concrete Ceilings drill four 5/16" (8 mm) dia.
holes to a minimum depth of 1-3/4" (45 mm). Attach
upper ceiling bracket (A) using concrete expansion
anchors as shown (right). Tighten to 80 in. • lb (9
N.M.) maximum torque.

CONCRETE ANCHOR INSTALLATION

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the ceiling will safely support four times the combined load of the equipment and all attached hardware

and components.

WARNING

• Make sure that the ceiling will safely support the

combined load of the equipment and all attached
hardware and components.

• Never exceed the Max. Load Capacity of 300 lb (137 kg).

WARNING

Figure 1

• Tighten concrete anchor bolt firmly, but do not over-

tighten. Overtightening can damage the bolt, greatly
reducing its holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

• Always attach concrete expansion anchors directly to

load-bearing concrete.

• Never attach concrete expansion anchors to concrete

covered with plaster, drywall or other finishing material.
If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown in Figure 1.

WARNING

1

3

2

CEILING

CEILING PLATE