Fixing

The appliance must be installed

on a perfectly level

supporting surface.
Any deformities caused by improper fi xing could affect
the features and operation of the hob.
The thickness of the supporting surface

should be taken

into account when choosing

the length of the screws for the

fi xing hooks:
• 30 mm thick: 23 mm screws
• 40 mm thick: 13 mm screws
Fix the hob as follows:
1. Use short fl at-bottomed screws to fi x the 4 alignment
springs in the holes provided at the central point of each
side of the hob.
2. Place the hob in the cavity, make sure it is in a central
position and push down on the whole perimeter until the
hob is stuck to the supporting surface.
3. For hobs with raised sides: After inserting the hob into its
cavity, insert the 4 fi xing hooks (each has its own pin) into
the lower edges of the hob, using the long pointed screws
to fi x them in place, until the glass is stuck to the supporting
surface.

!

The screws for the alignment springs must remain

accessible.

!

In order to adhere to safety standards, the appliance

must not come into contact with electrical parts once it
has been installed.

!

All parts which ensure the safe operation of the

appliance must not be removable without the aid of a
tool.

Electrical connection

!

The electrical connection for the hob and for any built-

in oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.

Single-phase connection

The hob is equipped with a pre-connected electricity
supply cable, which is designed for single-phase
connection. Connect the wires in accordance with the
instructions given in the following table and diagrams:

Voltage and

mains frequency

Electrical cable

Wire connection

220-240V 1+N ~

50 Hz

: yellow/green

N

: the two blue wires together

L

: brown and black together

Other types of connection

If the mains supply corresponds with one of the
following:

Voltage and mains frequency

• 400V - 2+N ~ 50 Hz

• 220-240V 3 ~ 50 Hz

• 400V 3 - N ~ 50 Hz
• 400V - 2+2N ~ 50 Hz

Separate the wires and connect them in accordance
with the instructions given in the following table and
diagrams:

Voltage and

mains frequency

Electrical cable

Wire connection

400V - 2+N ~

50 Hz

220-240V 3 ~

50 Hz

400V 3-N ~

50 Hz

: yellow/green;

N: the two blue wires
together
L1: black
L2: brown

400V - 2+2N ~

50 Hz

: yellow/green;

N1: blue
N2: blue
L1: black
L2: brown

Connecting the electricity supply cable to the mains

If the appliance is being connected directly to the
electricity mains an omnipolar switch must be installed
with a minimum opening of 3 mm between contacts.

!

The installer must ensure that the correct electrical

connection has been made and that it is fully compliant
with safety regulations.

Before connecting the appliance to the power supply, make
sure that:
• The appliance is earthed and the plug is compliant with

the law.

• The socket can withstand the maximum power of the

appliance, which is indicated on the data plate located on
the appliance itself.

• The voltage falls within the range of values indicated on

the data plate.

• The socket is compatible with the plug of the appliance.

If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.

!

Once the appliance has been installed, the power

supply cable and the electrical socket must be easily
accessible.

!

The cable must not be bent or compressed.

!

The cable must be checked regularly and replaced by

authorised technicians only.

!

The manufacturer declines any liability should these

safety measures not be observed.
! Do not remove or replace the power supply cable
for any reason. Its removal or replacement will void
the warranty and the CE marking. INDESIT does not
assume liability for accidents or damage arising from
replacement/removal of the original power supply cable.
Replacement can only be accepted when carried out by
personnel authorised by INDESIT and using an original
spare part.