Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

AM-FSpwSGSeries_EN.doc Nov-13

SG Series

Industrial Brackish Water RO Elements

The S-Series family of proprietary thin-film reverse
osmosis membrane elements is characterized by
high sodium chloride rejection and a smooth, foul-
ing-resistant membrane surface.
SG Brackish Water Elements are used for brackish
water desalination and process stream concentra-
tion.
The SG elements feature either a patented cage or
fiberglass outer wrap and 30mil or 50mil spacer.

Table 1: Element Specification

Membrane

S-Series, Thin-film membrane (TFM*)

Model

Average

permeate flow
gpd (m

3

/day)

1,2

Average NaCl

rejection

1,2

Minimum

NaCl

rejection

1,2

SG2540F30

590 (2.2)

98.5%

97%

SG2540F50

370 (1.4)

98.5%

97%

SG4040C30

2,200 (8.3)

98.5%

97%

SG8040F30

8,400 (31.8)

98.5%

97%

1

Average salt rejection after 24 hours operation.

Individual flow rate may vary ±25%.

2

Testing conditions: 2,000ppm NaCl solution at 225psi (1,551kPa) operating pres-

sure, 77°F (25°C), pH 6.5 and 15% recovery.

Model

Spacer

mil (mm)

Active area

ft

2

(m

2

)

Outer wrap

Part

number

SG2540F30

30 (0.76)

27 (2.5)

Fiberglass

1207546

SG2540F50

50 (1.27)

17 (1.6)

Fiberglass

1207547

SG4040C30

30 (0.76)

100 (9.3)

Cage

1207577

SG8040F30

30 (0.76)

380 (35.3)

Fiberglass

1207614

Figure 1a: Element Dimensions Diagram (Female)


Table 2: Dimensions and Weight

Model

1

Dimensions, inches (cm)

Boxed

A

B

2

C

3

Weight

lbs (kg)

SG2540F30

40.0

(101.6)

0.75

(1.90) OD

2.4

(6.1)

4

(1.8)

SG2540F50

40.0

(101.6)

0.75

(1.90) OD

2.4

(6.1)

4

(1.8)

SG4040F50

40.0

(101.6)

0.625

(1.59)

3.9

(9.9)

9

(4.1)

SG4040C30

40.0

(101.6)

0.625

(1.59)

3.9

(9.9)

9

(4.1)

SG8040F30

40.0

(101.6)

1.125

(2.86)

7.9

(20.1)

29

(13.2)

1

These elements are dried then bagged before shipping.

2

Internal diameter unless specified OD (outside diameter).

3

The element diameter (dimension C) is designed for optimum performance in GE

pressure vessels. Other pressure vessel dimension and tolerance may result in
excessive bypass and loss of capacity

Table 3: Operating and CIP Parameters

Typical Operating Flux

5 – 20 GFD (8 – 34 LMH)

Maximum Operating Pressure

600psi (4,137kPa) if T < 95°F (35°C)
435psi (3,000kPa) if T > 95°F (35°C)

Maximum Temperature

Continuous Operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)

pH Range

Optimum Rejection: 5.5-7.0,
Continuous Operation: 2.0-10.0,
Clean-In-Place (CIP): 1.0-10.5

Maximum Pressure Drop

Over an element 15psi (103kPa)
per housing: 60psi (414kPa)

Chlorine Tolerance

500+ ppm hours,
dechlorination recommended

Feedwater

NTU < 1
SDI < 5

Advertising