MANUAL SUPER POWER Series 325 HYD Model 325

01/05/2004

5

The oil reservoir/tank with return filter and suction strainer should be as close to the pump as

possible and on charge. Meaning that the level of the oil should be above the pump, preferably

with the oil tank above the water line.
For future maintenance, make sure that the return filter is easily accessible. An isolation valve

can be fitted to the suction.

The pump can be driven by either an internal combustion engine (crankshaft pulley or gearbox

PTO) or an electric motor. Depending on the speed and choice of drive, but should always
comply with the rated pressure/flow of the thruster.

For an internal combustion engine with fixed or variable speed, 3 types of pumps can be used,
depending on the unit to be fitted:

Direct PTO:

Fixed flow pump (***)

Variable displacement pump, depending on the model (**) (*)
Fixed flow pump with bypass (**) (*)

PTO with clutch:

Fixed flow pump (**) (*)
Variable displacement pump depending on the model (**) (*)

Fixed flow pump with bypass (**) (*)

On a DC or AC electric motor the following types of pumps can be used:

DC MOTOR:

Fixed flow pump (*)

AC MOTOR:

Fixed flow pump or other (**) (*)


(***) always require oil cooler

(**) require oil cooler when time of operation exceeds 15 minutes,

(*) oil cooler not necessary
Note: The above choices also depend on capacity of the oil tank etc.

The hydraulic directional control valve (DCV) must be equipped with a pressure gauge and
pressure relief valve and should preferably be placed as close as possible to the thruster unit.

The piping can be flexible or a mix of rigid and flexible type and should have crimp-connected

fittings.

The piping should match interior diameters and the service pressure equal or above that which
has been recommended.

The circuits must be as direct as possible and avoid any bends and joints.

The circuits must be clean and closed-off until final connection takes place.
The thruster hoses arriving at the thruster must be of the thermo-plastic non-conductive type.

The hydraulic motor drain line and the return T-line of the DCV should each go separately and
directly, back into the top of the oil tank.

Use synthetic, mineral or vegetable hydraulic oil, to ISO standard 32 to 48


8)

HYDRAULIC SPECIFICATIONS

SUPER POWER Series 325HYD Model 325: Flow =38/45 litres/Min; Pressure =210/240 bars

Detailed instructions and diagrams are delivered with each pack, specific to the installation
chosen.