MAX Power VIP 150 Electric Retractable Thruster User Manual

Page 9

Advertising
background image

VIP 150, 12/24V with Electronic Controller

.

25/12/05

9


4.2 POWER CABLE SELECTION:

According to the ISO 10133 standards:

“The length and cross sectional area of conductors in

each circuit shall be such that the calculated voltage drop shall not exceed 10% of the

nominal battery voltage at any appliance if the circuit is switched on at full load”.

The cable lengths as given in the table below are the total length of the positive cable,

measured from the thuster battery bank to the thruster, plus the total length of the negative

cable measured from the thruster back to the battery bank.




When choosing or calculating the cable size needed for your thruster installation, do not

forget to take into account the thermal rating of the conductor insulation which are directly
related to the ampacity (current carrying capacity) of the cable. Always try to use cables with

the highest thermal insulation rating available or at least 85° - 90°C.

For large diameter cables it may be easier to use two smaller cables instead (in order to allow

for a greater flexibility of movement). For example: 2 x 50 mm² instead of 95 mm². Cables at

thruster unit should be free to move, without kinking when VIP goes up and down.

4.3 POWER

FUSE:

Sizing of fuses for overcurrent protection are a function of the cable sizes in the circuit, not

the amperage drawn by the appliance (thruster motor) in the circuit. It is thus not the
electrical thruster motor that is protected by the fuse, but the power cables supplying the

thruster motor.

Fuse

Fuse
Holder

VIP 150, 12V VIP 150, 24V

Max Power Fuse Size

315 A

200 A

Regular Fuse Rating

600 A

300 A

Max Power Part Number

for fuse.

OPTI 3121

OPTI 3112

Max Power Part Number

for fuse holder.

OPTI 3091

OPTI 3119

VIP 150, 12V

VIP 150, 24V

Cable Lengths

From battery to thruster (+) & back (-)

mm²

AWG

mm²

AWG

5 m (2 x 2.5m)

95 mm²

3/0

50 mm²

1

10 m (2 x 5.0m)

120 mm²

4/0

70 mm²

2/0

15 m (2 x 7.5m)

185 mm² 350MCM

95 mm²

3/0

20 m (2 x 10m)

240 mm² 500MCM 120 mm²

4/0

The Max Power fuse has been application selected for it’s
time and current characteristics, consequently a much

lower rated fuse than traditionally rated may be fitted. Max
Power recommends the following fuses and fuse holders as

supplied by Max Power:

Advertising