OPERATION MANUAL

• INTRODUCTION

Clamp meter is 3 1/2 digit LCD and standard 9V battery
operation for measuring DC voltage, AC and DC current,
resistance and continuity test. All overload protection is
provided. It is matching with 500V insulation test attach-
ment for insulation test function. The knob switch design
makes manual operation workable & function selector,
range selector and power switch are all on one knob. It is
a good tool for electric measurement.

• GENERAL SPECIFICATION

1. Display: 3 1/2 digit LCD and max. 1999 counts.
2. Polarity : Auto
3. Over range indication: Only the MSD “1” display.
4. Sampling rate: 3 times per second.
5. Low voltage indication: “LOBAT” sign
6. Hold: Data hold
7. Power: 9V carbon-zinc battery or alkaline battery
8. Battery life: approx. 200 hours (alkaline battery)
Approx. 150 hours (carbon-zinc battery)

9. Working environment: 0˚C~50˚C,< 80% RH.
10. Storage environment: -20˚C~60˚C, < 80% RH.
11. Dimension: 230(L)mm x 70(W) mm x 37(D)mm.
12. Weight: approx. 310g (including battery).
13. Max. jaw opening: 50mm

• ELECTRICAL SPECIFICATION:

Accuracy is ± (percentage of reading + number of digit)
at 23±5˚C, <80%RH.

1.AC current

Range

Accuracy

Resolution

200A

±

(3%+5d)

100mA

1000A

±

(3%+5d)

1A

Frequency response: 50~60Hz
Indication: Average (rms of sine wave)

2. DC voltage

Range

Accuracy

Resolution

1000V

±

(0.8%+2d)

1V

Input impedance: 9MΩ
Max. overload protection: 1000 V DC

3. AC voltage

Range

Accuracy

Resolution

750V

±(1.2%+4d)

1V

Frequency response: 50~400Hz
Input impedance: 9MΩ
Max. overload protection: 750 V AC rms

4. Resistance

Range

Accuracy

Resolution

200Ω

±(1%+3d)

0.1Ω

20kΩ

±(1%+1d)

10Ω

Max. overload protection: 250 V DC / AC rms

5. Continuity test

Range: 200Ω
When resistance less than 75Ω build-in buzzersounds.
Max. overload protection: 250VDC/AC RMS

6. High resistance

(with 500V Insulation attach-

ment)

Range

Accuracy

Resolution

20MΩ

±

(2%+2d)

10KΩ

2000MΩ

≤500MΩ

±

(4%+2d)

1MΩ

>500MΩ

±

(5%+2d)

• FRONT PANEL DESCRIPTION:

• OPERATION:

1. AC current measurement:

a. Set the knob switch to ACA 1000A position.
b. Set the hold switch is loosing state.
c. Press the “PRESSURE” down and clamp a wire. If

clamp two or over wire, measure is useless.

d. If the reading less than 200A, change the range to

“200A” position in order to improve the Resolution.

e. If in dark, press hold switch, and read the data in

light place.

2. AC and DC voltage measurement:

a. Set the knob switch to DCV1000V or ACV750V po-

sition.

b. Set the hold switch is loosing state.
c. Connect the red lead to “V/Ω” jack and the black

lead to “COM” jack.

d. Connect the probes across circuit to be tested.

3. Resistance measurement:

a. Set the knob to proper resistance position.
b. Set the hold switch is loosing state.
c. Connect the red test lead to “V/Ω” jack and the test

black lead to “COM” jack.

d. Connect the probes across resistance to be tested.
e. When checking in-circuit resistance, be sure the cir-

cuit under test has all power removed and that all
capacitor are fully discharged.

4. Continuity test:

a. Set the knob switch to 200Ωposition.
b. Connect the test lead to “V/Ω” jack and the test black

lead to “COM” jack.

c. If resistance value less than 75Ωbetween two test

leads, buzzer sounds.

5. High resistance measurement:

a. Set the knob switch to “EXTERNAL UNIT” 20MΩ or

2000MΩ position, reading is unstable.

b. Connect three plugs of test attachment to corre-

spond jacks on front panel.

c. Set the knob switch and attachment switch to

2000MΩ position separately.

d. Connect resistance to input terminal of attachment.
e. Set power switch of attachment to “ON” position,

press “PUSH” button, indication lamp is light and
reading. If reading less than 19MΩ, separately
change meter and attachment range switch to
20MΩ in order to resolution.

Note:
1. 500V insulation attachment is optional accessories.
2. If 500V insulation attachment low voltage indication

lamp is light, should replacement battery.

• MAINTENANCE:

1.Your Digital Multi-meter is a preci-

sion electronic device. To avoid dam-
age, do not tamper with the circuitry.

Note:

a. Don’t input over 1000VDC or 750Vrms.
b. Don’t input voltage signal on resistance range.
c. Before replacement battery, must remove leads

from circuit and be turn off power.

2. Replacement battery:

If appears “LOBAT” on LCD, user should immediately
replace battery.

OFF

OFF

20MΩ

20MΩ

2000MΩ

2000MΩ

200

1000

200

1000

ACA

ACA

EXTERNAL UNIT

EXTERNAL UNIT

20K

200

20K

200

ACV

750

DCV

1000

DCV

1000

ACV

750

WITH 261 OPTION (500V) INSULATION TESTER

MT-3266

3 1/2 HAND HELD DIGITAL

CLAMP METER

VΩ

EXT

COM

1000V

750V~

MAX

HOLD

PROKIT’S INDUSTRIES CO., LTD.

http://www.prokits.com.tw

E-mail : [email protected]

Clamp

Pressure

Hold switch

Knob switch

LCD

Hand bell

COM terminal

V/Ω INPUT terminal

Insulation
attachment
terminal

©2012 Prokit’s Industries Co., LTD. All rights reserved. 2012001(C)

Advertising