Resistance, Frequency, Audible continuity and diode – Prokit's Industries 3PK-9912 User Manual

Page 12: Replacing the battery, Warning

Advertising
background image

1000A 1A

> 600A ±3.0% of rdg ± 5 digits

Overload Protection: 1200A for 60 seconds maximum.

-9-

RESISTANCE

Range Resolution

Accuracy

300

Ω 0.1Ω

3k

Ω

1

Ω

30k

Ω 10Ω

300k

Ω 0.1kΩ

3M

Ω 1kΩ

±2.0% of rdg ± 10 digits

30M

Ω 10kΩ

±2.5% of rdg ± 10 digits

Maximum Open Circuit Voltage: 1.3V
Overload Protection: 250V dc or rms. ac for all ranges.

FREQUENCY

Range Resolution

Accuracy

30kHz 10Hz

±2.0% of rdg ± 10 digits

Sensitivity: 200mV rms.

Input Limit: 250V ac.

AUDIBLE CONTINUITY AND DIODE

Range

Description

If continuity exists (about less than 18

Ω), built-in buzzer will sound.

Show the approx. Forward voltage of the diode.

REPLACING THE BATTERY

WARNING

Before attempting to open the case of battery, always be sure that test leads

have been disconnected from measurement circuits. Close case and tighten