1-3 Electrical Specifications
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C < 80%RH.
Temperature coefficient:

0.2 x (Specified accuracy) / °C < 18°C, > 28°C .

Voltage

Function

Range

Accuracy

4V ~ 400.0V

±(0.8%+ 4dgt)

ACV

600.0V ±(1.2%+

4dgt)

4V ~ 400.0V

±(0.7% + 4dgt)

DCV

600.0V

±(0.8+% + 5dgt)

Overload protection:

600 Vrms

Max Operation time:

DT=30s for 30V

Input impedance:

4K for input

voltage up to 30V. Impedance increase with input voltage

to approximate 200KΩ at 600V.

When measurement value less than 2V AC voltage or 200mV DC voltage, LCD monitor

will display “AUTO” symbol and non values.

Resistance

Function Range

Accuracy

400Ω

±(0.8% + 6 dgt)

4kΩ~4MΩ

±(0.8% + 2 dgt)

Ω  

40MΩ

±(2.0% + 5dgt)

Overload protection:

600V rms

Max. open circuit voltage:

1.5V

Temperature coefficient multiply by 1.5 when operating temperature is temperature is 40°C

~ 50°C .

ACA

Function Range

Accuracy

ACA

(50-60Hz)

 

40.0~400.0A ±(1.8%+5

dgt)

 

2

Advertising