AC-DC Converters

JB300 Series

300 Watts

Dual Output

Switching Power Supply

Features

Ultra compact 300W with 1U height Power Density: 8.3 watts/cu in

5/ 12/ 24/ 48V Dual Output Optional Combinations

Power Factor Corrected to EN61000-3-2 class A

Approved to UL CUL TUV CB and CE

AC Input Range Auto-Selectable

4 - Mechanical Options

Input Voltage:

90-132 / 180-264Vac auto-ranging, 47~63Hz.

Input Current:

8/4A at 100-120/200-240Vac.

Inrush Current:

Max. 70A@230Vac & 35A@115Vac; cold start.

PFC:

Power Factor Correction pass EN61000-3-2 class A.

Transient Response:

Returns to within 1% in less than 2.5mS for a 50% load change and the peak transient does not excess 5%.

Overshoot:

Turn-on & off overshoot < 5% over nominal voltage.

Efficiency:

75% minimum (Measuring at 230V and full load).

Turn On Delay:

1 second maximum at 120 Vac.

Hold Up Time:

20mS min. at 80% of full load.

Adjustability:

Output user adjustable +/-5% minimum.

Fan Drive:

12VDC/400mA to drive an external fan.

Fan Fail (FF) Alarm:

Designated as FF on pin 3 of CN1 is a open collector output rated for 15VDC/5mA sink current maximum, it will
go high when a fan failure is detected.

Power Supply On:

Green LED designated as LED1 on the PCB.

Power Good:

Designated as PG on CN1 and TTL high 100-500mS after regulation. It goes low at least 1mS before loss of
regulation and has ability to sink 100mA.

Input Fusing Protection:

One T8A/250V fuse inserted in primary.

Over-Power Protection:

C.C. mode 110~140% and auto-recovery.

Short Circuit Protection:

Trip without damage and auto-recovery.

Over Voltage Protection:

Unit latching down when output exceeds 130% and recycle AC input to reset.

Over-Temperature Protection:

Unit protected for excessive operating ambient 85°C, and automatic recovery.

Switching Frequency:

23K Hz fixed frequency.

Operating Temperature:

0 to 70°C ambient, de-rating at 2.5% per degree from 50°C to 70°C.

Storage Temperature:

-20 to 85°C.

Operating Humidity:

5% to 90% RH, Non-condensing.

Storage Humidity:

5% to 95% RH, Non-condensing.

Emissions:

FCC Part 15, CISPR 22 class B, EN55022’B’ Conducted, EN61000-3-2,3 & IEC61000-4 Series Regulations

Vibration:

5 ~ 50 Hz, acceleration 7.35 m/s*s on X,Y and Z Axis.

Safety Regulation:

Approved to UL60950-1, CSA C22.2 No. 60950-1-03, TUV EN60950-1, CE Mark (LVD) and CB.

Leakage Current:

Standard model 1.5mA @ 240Vac. (optional for 500uA max. at 240Vac / 300uA max. at 120Vac input)

HI-POT Test:

1500 VAC input line to chassis (10mA DC cut off current); Isolating 3000VAC primary to secondary windings;
Primary to core 1500VAC. All for 3 sec.

Grounding Test:

Apply 25 A from ground pin of the three prong plug to the far most earth. Max allowable resistance 0.1 ohm.

MTBF:

100000 Hrs (according to MIL-HBK-217F) at 30°C.

Cooling:
U Type:

U-Chassis @300W max. with 18CFM airflow or 150W max. convection cooling

C Type:

U-Chassis with top cover @150W max. convection cooling

E Type:

Enclosed with end built-in fan @300W max.

F Type:

Enclosed with top built-in fan @300W max.

Electrical Specification