DC-DC Switching Regulator

SR20-12W Series
20A SIP & SMT Packages
Non-Isolated

Features

Non-Isolated POL Converter

SIP / SMT Packages

Output Current 20A

Input Voltage Range 6 - 14VDC

Output Voltage Range 0.7525 - 5VDC

Efficiency to 94%

Over Temperature Protection, Remote On/Off Control

Continuous Short Circuit Protection

Output Voltage Sequencing, Power Good Signal

INPUT
Input Voltage Range

6.0 - 14V (12V nominal)
6.5 - 14V (5.0V out version)

Under Voltage Lock-out

5.0V typ. (Power Up)
4.0V typ. (Power Down)

Input Filter

Capacitive

Remote On/Off Control

Open Circuit or equal to Vin (Module On)
<0.4VDC (Module Off)

OUTPUT
Voltage Accuracy

±1.5% max.

Transient Response: 25% step load change

<200µ sec.

Ripple and Noise (20MHz BW) [3]

30mV rms, 75mV pk-pk max.

Temperature Coefficient

±0.03% / °C

Short Circuit Protection

Continuous

Line Regulation [1]

±0.2%

Load Regulation [2]

±0.5%

Capacitive Load, Low ESR

8000µF max.

External Trim Adj. Range

Vo = 0.75 - 5.0VDC

Sequencing Slew Rate Capability (dVseq/dt)

0.1 - 1.0V / m sec.

Sequencing Delay Time

10m sec.

Tracking Accuracy

200mV max. (Power Up)
400mV max. (Power Down)

Power Good Signal Asserted Logic High

Vo = 90% - 100% Vo nom.

GENERAL
Efficiency

See Table

Isolation Voltage

Non-Isolated

Switching Frequency

300KHz typ.

Over Temperature Protection

130°C typ.

Operating Temperature Range

-40°C to +85°C

Power Derating

See derating curves

Storage Temperature Range

-55°C to +125°C

Dimensions

61.0 x 12.95 x 8.30 mm (2.40 x 0.51 x 0.327 Inches) (SIP Package)
43.2 x 13.46 x 9.3 mm (1.70 x 0.53 x 0.366 Inches) (SMT Package)

Case

Non-potted open frame type

Weight

11g

Electrical Specification

Typical at nominal line, full load & 25°C unless otherwise stated.

NOTE:
1. Measured from High Line to Low Line (Vo set to 3.3VDC).
2. Measured from Full Load to No Load (Vo set to 3.3VDC).
3. Output noise & ripple is measured with a 10µF tantalum & 1µF ceramic capacitor across the output.
4. It is recommended to put a 200µF capacitor with ESR<25mΩ across the input to reduce the input ripple voltage.
5. Suffix ‘N’ to model number for Negative Logic Remote On/Off Control.
6. Suffix ‘P’ to model number for Power Good function.