SPECIFICATIONS

Rev. Sept. 2012

Di men sions

Eurorack mount ing

with front panel FP40

Wall mount ing with

front panel FPW

Re dun dant adapter

RA 10 for S28 - 10

An a log Pro gramming

CV

CC

Pro gramming in puts

in put range
ac cu racy
in put im ped ance

0 - 5 V

± 0.2% - 5 mV / + 12 mV

5 kOhm

0 - 5 V

± 0.5% - 4 mV / + 20 mV

5 kOhm

Mon i toring out put

out put range
ac cu racy
out put im ped ance

not avail able

0 - 5 V

± 0.5% − 6 mV / + 0 mV

20 Ohm

Re cov ery time

50 - 100% load step

: 100 µs S6-40, S28-10

200 µs S15-18

In su la tion

In put/Out put

: 3750 Vrms (1 min.)

8 mm creepage/clear ance

In put/case

: 2500 Vrms (1 min.)

Out put/case

: 500 V DC

Safety

: EN 60950 EN 61010

EMC

Power Sup ply Stan dard : EN 61204-3
Ge neric Emis sion

: EN

61000-6-3

(EN

55022B)

Ge neric Im mu nity

: EN

61000-6-2

Op er at ing am bi ent temp. : –20 to +50 °C

Ther mal pro tec tion

: Out put shuts down in case

of in suf fi cient cool ing

Se ries op er a tion

: Max. 500 V to tal volt age

Re mote sens ing

: Max. 2 V per lead

OVP ad

just range

: 5 - 35 V

Mount ing

: Ver ti cal air flow through the

unit should not be ob -
structed

Cooling

: Nat u ral con vec tion cool ing,

no blower, no noise.

MTBF

: 500

000 hrs

Standby in put power

: 4 W

Hold-up time

100 % load, 220 V AC : 20 ms
50 % load, 220 V AC : 40 ms

Di men sions (h x w x d)

: 106 x 194.5 x 166 mm

Case

: DIN 41494 / IP20

Con nec tors

: H15 (DIN 41612)

Weight

: 2.8 kg