Specifications typical applications, Isolated analog controller interface – Powersolve SM3300 Interfaces User Manual

Page 2

Advertising
background image

SM3300 INTERFACES

Page 1 - 2

SPECIFICATIONS

Nov.2012, Preliminary version

An a log Pro gram ming

CV

CC

Pro gram ming in puts

in put range
ac cu racy
off set
temp. coeff. off set
in put im ped ance

0 - 5 V

± 0.2%

- 1 ... +1 mV (on 5V)

10 µV / °C

10 MOhm

0 - 5 V

± 0.2%

- 1 ... + 1 mV (on 5V)

10 µV / °C

10 MOhm

Mon i tor ing out put

out put range
ac cu racy
off set
temp. coeff. off set
out put im ped ance

0 - 5 V

± 0.2%

- 1... 1 mV (on 5V)

3 µV / °C

2 Ohm / max. 4 mA

- 5 V to + 5 V

± 0.2%

- 1... 1 mV (on 5V)

60 µV / °C

2 Ohm / max. 4 mA

Ref er ence volt age

on prog. con nec tor

V

ref

TC

5.114 V ± 15 mV (Ro = 2 Ohm, max. 4 mA)

20 ppm

+12 V out put

V

o

on prog. Con nec tor

I

max

R

o

12 V ± 0.2 V

0.2 A

5 Ohm

Sta tus out puts

CC - sta tus
LIM- sta tus
OT

- sta tus

PSOL

- sta tus

ACF

- sta tus

DCF

- sta tus

CC - op er a tion

5 V = logic 1 (R

o

= 500 Ohm)

CV or CC limit

5 V = logic 1 (R

o

= 500 Ohm)

Over Tem per a ture

5 V = logic 1 (R

o

= 500 Ohm)

Power Sink Over load

5 V = logic 1 (R

o

= 500 Ohm)

AC - Fail

5 V = logic 1 (R

o

= 500 Ohm)

DC - Fail

2

)

5 V = logic 1 (R

o

= 500 Ohm)

2

) out put volt age ± 5% be yond set point

Re mote Shut Down

with + 5V, 1 mA or re lay con tact

In su la tion
prog. con nec tor - in ter nal cir cuits
prog. con nec tor - earth

1000 VDC Re in forced iso la tion acc. EN60950-1 / EN61010-1

max. 60VDC

Safety

EN 60950 / EN 61010

Op er at ing Tem per a ture

− 20 to + 50 °C

Hu mid ity

max. 95% RH, non con dens ing, up to 40 °C
max. 75% RH, non con dens ing, up to 50 °C

Stor age tem per a ture

− 40 to + 85 °C

Mount ing

Pluggable, SM3300 in ter face slots 2, 3, 4.

See para graph 'Hard ware In stal la tion' in this man ual.

Note1: can not be plugged in slot1

Note2: max 1pcs MOD INT ANA per unit.

Pro gram ming con nec tor

15 pole D-con nec tor (fe male)

Weight

0.14 kg

Specifications

Typical Applications

• Analog programming of voltage and current

• Remote monitoring of the status signals: OverTemp, Limit, PowerSink OverLoad

• Analog monitoring of voltage and current

• Remote Shut down of the power output using a 5V signal

Isolated Analog Controller interface