DC-DC Converters

TEN 20WIN Series
20 Watt

MODEL INPUT

OUTPUT

OUTPUT

CURRENT

VOLTAGE VOLTAGE

MAX.

TEN 20-2410WIN

3.3 VDC 5500 mA

TEN 20-2411WIN

5 VDC 4000 mA

TEN 20-2412WIN

12 VDC

1670 mA

TEN 20-2413WIN

9 – 36 VDC

15 VDC

1330 mA

TEN 20-2421WIN

±5 VDC

±2000 mA

TEN 20-2422WIN

±12 VDC

±835 mA

TEN 20-2423WIN

±15 VDC

±665 mA

TEN 20-4810WIN

3.3 VDC 5500 mA

TEN 20-4811WIN

5 VDC 4000 mA

TEN 20-4812WIN

12 VDC

1670 mA

TEN 20-4813WIN

18 – 75 VDC

15 VDC

1330 mA

TEN 20-4821WIN

±5 VDC

±2000 mA

TEN 20-4822WIN

±12 VDC

±835 mA

TEN 20-4823WIN

±15 VDC

±665 mA

Features

High Power Density in 51x25x10mm Metal Package

Ultrawide 4:1 Input Range

High Efficiency up to 86%

Operating Temperature Range –40°C to +85°C

I/O Isolation 1500 VDC

Short Circuit Protection

Remote On/Off

Adjustable Output Voltage

Industry Standard Pinout

Pending

Pin

Single Output

Dual Output

1

+ Vin (Vcc)

+ Vin (Vcc)

2

– Vin (GND)

– Vin (GND)

3

+ Vout

+ Vout

4

Trim

Common

5

– Vout

– Vout

6

Remote On/Off

Remote On/Off

Pin Connection

Pin ø 1.0 mm (0.04)

2

3.

02

10.2

6

25.4

21

54

3

Bottom view

10.16

2.

51

2.5

Insulated
Baseplate

(1.0)

(0.1)

(0.4)

(0.24)

)

8.

0(

(0.4)

7.62

(0.3)

6

7.62

(0.3)

10.16

(0.4)

5.08

(0.2)

5

0

.8

(2

.0

)

(0

.6

)

() = Inches

Line regulation

±0.2% max.

Load regulation

– Single output models ±0.5% max.

– Dual output models ±3.0% max.

Output voltage adjustment

Single output models only: ±10% (by external resistor)

Ripple & Noise

– Single output models: <75 mVpk-pk (20 MHz BW)

– Dual output models: <100 mVpk-pk (20 MHz BW)

Conducted EMI

EN 55022, class A and FCC, level A

(with external capacitor)

Short circuit protection

continuous, automatic recovery

Efficiency

85% typ.

Operating temperature range

–40°C … +85°C above 65°C derating 2.5%/°C

I/O isolation voltage

1500 VDC

Safety standards

cUL/UL 60950-1, IEC/EN 60950-1

Case

metal, with insulated baseplate

Remote On/Off

shutdown input for low input current (2.5 mA) in

standby operation

Electrical Specification

Advertising