3B Scientific Electroscope User Manual

Instruction sheet

Advertising
background image

3

Instruction Sheet

3B SCIENTIFIC® PHYSICS

U17250 Electroscope

6/03 ALF

®

The device is used for an introduction into the funda-
mentals of electrostatics and for displaying DC and AC
voltages as well as demonstrating the operating prin-
ciples of high voltage meters according to Braun.

1. Safety instructions

• Make sure that the insulator is always clean and

dry. If necessary use alcohol or spirits for cleaning.

• At high humidity and after transporting the unit

from a cool room into a warmer one, dry the elec-
troscope in a stream of hot air (e.g. a hair dryer).

2. Description, technical data

The electroscope consists of a metal baseplate on which
the iron shielding ring for defined field distribution is
mounted. The iron ring is equipped with a 4-mm socket
for earthing purposes. The support for needle with
pivot bearing is attached electrically insulated to the
shielding ring. The pointer is suspended asymmetri-
cally and so its weight delivers the restoring moment.
Inside the electrically conductive insulator at the up-
per part of the device there is a 4-mm socket for mount-
ing the sphere and capacitor plate.
For demonstration experiments the electroscope is suit-
able for shadow projection using a point source light.
Diameter:

130 mm

2.1 Scope of supply
1 Electroscope
1 Sphere with 4-mm plug
1 Capacitor plate with 4-mm plug
1 Capacitor plate on insulating rod

3. Operation

The electroscope is charged using friction rods stati-
cally charged by various friction-inducing materials
(e.g. U11053), or using a high-voltage power supply unit
(e.g. U21060).

3.1 Charging up the electroscope by touching it

with a statically charged body

Attach the sphere or capacitor plate to the elec-
troscope.

Rub the friction rod with the suitable material (PVC
or acrylic rods e.g. with plastic foil).

Touch the sphere or capacitor plate with the
charged rod. The pointer deflects.

Remove the friction rod, the pointer remains de-
flected.

Touch the sphere with your hand. The pointer re-
turns to normal.

When a high-voltage power supply is used then
attach the capacitor plate to the positive pole of
the power supply unit. Connect the negative pole

1

Sphere with 4-mm plug

2

Insulator

3

Shielding ring

4

Baseplate

5

Capacitor plate with 4-mm plug

6

Capacitor plate on insulating rod

7

4-mm socket

8

Support with pointer

1

2

3

4

5

6

7

8

Advertising