The purpose of the water-decomposition is for the elec-
trolysis of water (converting electrical energy into
chemical energy), quantitative determination of the
resulting gases and confirmation of Faraday’s laws.

1. Safety instructions

Since the conductivity of distilled water is too low,
electrolysis is carried out using dilute sulfuric acid
(c =1 mol/l approx.).

Carefully add the sulfuric acid to the water while
stirring. Never do this the other way round.

Wear protective goggles when mixing the solution
and when releasing the gases.

Students should always be informed of the dan-
gers of the chemicals needed for the experiment.

Caution. Any acid that escapes can cause irrepa-
rable stains and holes in clothing.

Be careful when taking the glass tubing off its se-
curing plate.

Do not subject the glass components of the water-
decomposition apparatus to mechanical stress.

2. Description, technical data

The water-decomposition apparatus consists of an H-
shaped section of glass tubing attached to a securing
plate fixed to a stand rod that rests on a base-plate.
The glass section involves two gas collection tubes each

U14332 Hofmann water-decomposition apparatus

11/03 ALF

with a measuring scale. At the top of each tube there
is a ground stopcock. Two platinum electrodes are se-
cured at the lower ends via GL-18 screw fittings. A flex-
ible plastic hose leads to a leveling bulb for equalising
the pressure in the collection tubes.

Dimensions:
Water-decomposition apparatus:

Height:

800 mm approx.

Width:

150 mm

Base-plate:

250 mm x 160 mm

Rod:

750 mm x 12 mm Ø

Securing plate:

120 mm x 110 mm

Gas collection tubes:

Height:

510 mm

Width:

150 mm

Tube diameter:

19 mm

Scale:

50 ml each with 0.2 ml divisions

Leveling bulb:

Volume:

250 ml

2.1 Scope of delivery:
1 Glass section with gas collection tubes
1 Base-plate with stand rod and securing plate
1 Pair of platinum electrodes with 4-mm sockets
1 Leveling bulb with plastic hose
1 Stand ring to hold the leveling bulb
1 Universal sleeve

1

Base-plate with stand rod

2

Platinum electrodes

3

GL-18 screw fitting

4

GL-14 screw fitting

5

Gas collection tubes

6

Securing plate

7

Ground stopcock

8

Plastic hose

9

Stand ring

bl

Leveling bulb

1

2

3

4

5

6

7

8

9

bl