3B Scientific Photo Gate User Manual

3b scientific, Physics

Advertising
background image


3B SCIENTIFIC

®

PHYSICS



1

Light barrier U11365

Instruction sheet

01/10 Hh/570012

1. Safety instructions

When using the equipment in conjunction with
a laser source, strictly observe the stipulated
safety regulations.

Never look directly into the laser beam.


2. Scope of delivery

1 Light barrier

1 Stand rod, length: 120 mm

1 8-pin mini DIN connection cable, length: 1 m

1 Knurled screw M6x1


3. Description

The light barrier can be used in two operating
modes.

1. Internal light barrier mode: light barrier with an
infrared light source and an infra-red detector with
a very short signal delay for measuring time inter-
vals with moving bodies, e.g. during free fall, in air

track experiments and for pendulum oscillations,
as well as for counting pulses.

2. Laser light barrier mode: laser diode detector
built in at the side for setting up a wide-range
barrier along with a laser pointer, e.g. during sport-
ing events.

The light barrier is equipped with a built-in LED
function display: beam broken = 1 (TTL high).
When disabled or when the beam is interrupted,
the LED function display comes on.

The narrow barrier arm in front of the infra-red
source includes a sliding mechanical shutter that is
used for disabling internal light-barrier mode and
activating laser light -barrier mode.


4. Technical data

Separation of prongs:

82 mm

Rise time:

60 ns

Spatial resolution:

< 1 mm

Time resolution:

10 µs