3B Scientific AC__DC Power Supply (Stabilized) 0-12 V, 3 A (230 V, 50__60 Hz) User Manual

Page 2

Advertising
background image

Elwe Didactic GmbH ▪ Steinfelsstr. 5 ▪ 08248 Klingenthal ▪ Germany ▪

www.elwedidactic.com

3B Scientific GmbH ▪ Rudorffweg 8 ▪ 21031 Hamburg ▪ Germany ▪

www.3bscientific.com

Subject to technical amendments

© Copyright 2012 3B Scientific GmbH

The instrument may only be connected to

the mains via a socket that has an earth

connection.

Before making any connections, check the

experiment leads for damaged insulation

and exposed wires.

Replace any blown fuses only with new

ones that match the specifications stated on

the rear of the housing

Disconnect the equipment from the mains

before replacing a fuse.

Never short the fuse or the fuse holder.

Never cover the air vents and heat sink at

the rear of the housing. These are neces-

sary in order to ensure sufficient circulation

of air required for cooling the components

inside the equipment.

The equipment may only be

opened/repaired by qualified and trained

personnel.


2. Description

The AC/DC power supply provides a continu-

ously adjustable, stabilised AC or DC voltage for

student exercises and experiments. Either AC or

DC output voltage is selected by means of a

toggle switch.
The power supply 1001006 is for operation with

a mains voltage of 115 V (±10%), and the unit

1001007 is for operation with a mains voltage of

230 V (±10%).


3. Technical data

Mains supply voltage: see back panel
Output voltages:

0 – 12 V

Output current:

2 – 8 V, 2 A

8 – 10 V, 3 A

10 – 12 V, 4 A

Output resistance:

50 mΩ approx.

Fuse rating:

4 A

Connections:

4 mm safety sockets

Dimensions: 162x170x68

mm

3

approx.

Mass:

2.9 kg approx.


4. Operation

It is recommended to use one of the following

instruments to measure the output voltage:
Analogue Multimeter AM50

1003073

or

Analogue Multimeter AM51

1003074

Caution:
The AC and DC outputs cannot be used at the

same time.

4.1 Obtaining an AC voltage

Connect the unit to the mains supply. Turn

the voltage control knob fully to the left.

Connect the load to the AC output sockets.

Set the toggle switch to AC.

Press the mains switch; the mains indicator

light shows green.

Set the required voltage using the voltage

control; if necessary, connect a voltmeter in

parallel with the load.

4.2 Obtaining a DC voltage

Connect the unit to the mains supply. Turn

the voltage control knob fully to the left.

Connect the load to the DC output sockets.

Set the toggle switch to DC.

Press the mains switch; the mains indicator

light shows green.

Set the required voltage using the voltage

control; if necessary, connect a voltmeter in

parallel with the load.

4.3 Changing the fuse

Before changing the fuse, unplug the unit

from the mains.

Using a screwdriver (or similar tool), un-

screw and lift out the fuse holder.

Replace the fuse with a new one with the

same specifications.

Screw the fuse holder back into place.


5. Care and maintenance

Before cleaning the equipment, disconnect it

from its power supply.

Use a soft, damp cloth to clean it.


6. Disposal

The packaging should be disposed of at

local recycling points.

Should you need to dispose of the equip-

ment itself, never throw it away in normal

domestic waste. Local regulations for the

disposal of electrical equipment will apply.