Dexter Laundry T-50X2 EXPRESS (Commercial) User Manual

Page 13

Advertising
background image

Instructions - Convert a Dual Voltage Stack Dryer

from 120V to 208-240V with Neutral Wire Only

1. Remove incoming power from the dryer. Use a known working voltmeter to check power.

2. Remove the cover of both the upper and lower control box assemblies from the dryer using a 5/16” wrench.

3. Move the black/blue wire from the N position of the main power terminal block to the L2 position of the main power

terminal block in the upper control box assembly. See Figure 6 below.

4. Move the white wire of the upper motor harness to an upper inner left terminal in the middle terminal block in the

lower control box assembly. See Figure 6 below.

5. Move the orange wire of the upper motor harness to an upper inner left terminal in the middle terminal block in the

lower control box assembly. See Figure 6 below.

6. Move the white wire of the lower motor harness to a lower inner left terminal in the middle terminal block in the

lower control box assembly. See Figure 6 below.

7. Move the orange wire of the lower motor harness to a lower inner left terminal in the middle terminal block in the

lower control box assembly. See Figure 6 below.

8. Reconnect power to the dryer and test to ensure proper operation; one line voltage to L1, one line voltage to L2,

the neutral to N, and the earth ground to E.

9. Reinstall the cover of both the upper and lower control box assemblies from the dryer using a 5/16” wrench.

Figure 6 - Dual Voltage Stack Dryer Voltage Conversion

13

Advertising