Setup – Crown Audio VRack12000HD User Manual

Page 9

Advertising
background image

page 9

Operation Manual

Setup

Type of Connectors to Use with VRack


L21-30

Mcaster-Carr

Female: 7184K35

Male: 7184K34

Hubbel Catalog

Female: HBL2813

Male: HBL2811

I

EC 309 Pin + Sleeve

Walther-Electric

Female: 330

Male: 230

Cooper Crouse-Hinds

Female: CH532C6W

Male: CH532P6W

VRack Power Distribution Overview

The VRack Power Distribution panel offers worldwide use capabilities as well as multiple AC operations when used with

120VAC input. This power distribution system allows 120VAC input to 120VAC output, 120VAC input to 208VAC output when

used with 3 phase power, 220VAC – 240VAC input to 220VAC – 240VAC output. It also features a 32A per circuit, 3-pole,

single-throw breaker as well as an LCD readout that indicates AC Voltage. Built-in +5V and +12V outputs power the VRack’s

built-in network switch and rear rack lighting features. Combine this worldwide capable power distro with the I-Tech HD’s

Universal, Power-Factor-Corrected Power Supply and the VRack can be used anywhere in the world.

Hubbell L21-30 U.S. Operation

Hubbell L21-30 12 120VAC Operation

Switch position “Input Twistlock, Output US/120” provides the user with 120V

operation to the I-Tech HD amplifiers in the rack. From an external power

distribution system, send 3 phase 120VAC power to the X, Y, and Z pin of the

Hubbell connector and the VRack will operate in 120V mode. Each I-Tech HD

amplifier will see a dedicated X, Y, or Z phase to the line input, neutral, and

Ground connection.

Amp 1 = X, Neutral, and GND

Amp 2 = Y, Neutral, and GND

Amp 3 = Z, Neutral, and GND

Hubbell L21-30 208VAC Operation

Switch Position “Input Twistlock, Output US/208” provides the user with

208VAC operation to the I-Tech HD amplifiers in the rack. From an external

power distribution system, send 3 phase 120VAC power to the X, Y, and Z

pin of the Hubbell connector and the VRack will operate in 208V mode. Each

I-Tech HD amplifier will see a dedicated line-to-line and ground connection

resulting in the VRack operating in 208VAC mode.

Amp 1 = X, Y, and GND

Amp 2 = Y, Z, and GND

Amp 3 = X, Z, and GND