Declaration of conformity, Important safety instructions, Fcc compliance notice – Crown Audio CTs Series (2 Channel) User Manual

Page 2

Advertising
background image

Operation Manual

CTs Power Amplifiers

page 2

page 3

CTs Power Amplifiers

Operation Manual

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with a dry cloth.

7. Do not block any ventilation openings. Install in accordance

with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat

reg isters, stoves, or other apparatus (including amplifiers)

that produce heat.

9. Do not defeat the safety purpose of the polarized or

grounding-type plug. A polarized plug has two blades with

one wider than the other. A grounding-type plug has two

blades and a third grounding prong. The wide blade or

the third prong is provided for your safety. If the provided

plug does not fit into your outlet, consult an electrician for

replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched,

par ticularly at plugs, convenience receptacles, and the

point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufac-

turer.

12. Use only with a cart, stand, tripod, bracket, or table

specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/

apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when

unused for long periods of time.

14. Refer all servicing to qualified service personnel. Servicing

is required when the apparatus has been damaged in any

way, such as power-supply cord or plug is damaged, liquid

has been spilled or objects have fallen into the apparatus,

the apparatus has been exposed to rain or moisture, does

not operate nor mally, or has been dropped.

15. Use the mains plug to disconnect the apparatus from the

mains.

16. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR

MOISTURE.

17. DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR

SPASHING AND ENSURE THAT NO OBJECTS FILLED

WITH LIQUIDS, SUCH AS VASES, ARE PLACED ON THE

EQUIPMENT.

18. THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL

REMAIN READILY OPERABLE.

Important Safety Instructions

MagNeTic FieLd

CAUTION! Do not locate sensitive high-gain equipment such as pre-

amplifiers directly above or below the unit. Because this amplifier has a

high power density, it has a strong magnetic field which can induce hum

into unshielded devices that are located nearby. The field is strongest

just above and below the unit.
If an equipment rack is used, we recommend locating the amplifier(s)

in the bottom of the rack and the preamplifier or other sensitive equip-

ment at the top.

The lightning bolt triangle is used to alert the user to the risk of

electric shock.
The exclamation point triangle is used to alert the user to

important operating or maintenance instructions.
RegaRdeZ ceS SYMBOLeS:
La triangle avec le sigle ‘’foudre’’ est employée pour alerter

l’utilisateur au risque de décharge électrique. Le triangle avec

un point d’exclamation est employée pour alerter l’utilisateur

d’instruction importantes pour lors opérations de mainte nance.
aTeNciON cON eSTOS SÍMBOLOS:
El triángulo con el símbolo de rayo eléctrico es usado para

alertar al usuario de el riesgo de un choque eléctrico.
El triángulo con el signo de admiración es usado para alertar

al usuario de instrucciones importantes de operación o man-

tenimiento.

WaTcH FOR THeSe SYMBOLS:

iMPORTaNT

CTs Series amplifiers require Class 2 output wiring.
Les amplificateurs de série de CTs exigent des câbles de sortie de
classe 2.
CTs-Reihe-Verstärker verlangen Klasse die 2 Produktionsverdrah tung.
Los amplificadores de la Serie CTs requieren de un cableado de sal ida
Clase 2.

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR

BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES

COUVERCLES. IL N’Y A PAS DES PARTIES SERVICEABLE

À L’INTÉRIEUR. TOUS REPARATIONS DOIT ETRE FAIRE PAR

PERSONNEL QUALIFIÉ SEULMENT.
PARA PREVENIR UN CHOQUE ELÉCTRICO, NO RETIRE LAS

CUBIERTAS SUPERIOR O INFERIOR. NO EXISTEN PARTES QUE

PUEDAN SER REPARADAS POR EL USUARIO AL INTE RIOR.

REMITA EL SERVICICO AL PERSONAL TÉCHNICAL CALIFI-

CADO.
TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE

AC MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG

FROM THE AC RECEPTACLE. THE MAINS PLUG OF THE POWER

SUPPLY CORD SHALL REMAIN READILY OPERABLE.
POUR DÉMONTER COMPLÈTEMENT L’ÉQUIPEMENT DE

L’ALIMENTATION GÉNÉRALE, DÉMONTER LE CÂBLE D’ALI-

MENTATION DE SON RÉCEPTACLE. LA PRISE D’ALIMEN TATION

RESTERA AISÉMENT FONCTIONNELLE.
PARA DESCONECTAR COMPLETAMENTE EL EQUIPO DEL

SUMINSTRO ELECTRICO, DESCONECTE EL CABLE DE ALI-

MENTACION DE LA TOMA DE CA. LAS PATAS DEL CONEC TOR

DEL CABLE DE ALIMENTACIÓN DEBERAN MANTENERSE EN

BUEN ESTADO.

FCC COMPLIANCE NOTICE

This device complies with part 15 of the FCC rules. Operation is subject to the following

two conditions: (1) This device may not cause harmful interference, and (2) this device

must accept any interference received, including interference that may cause undesired

operation.

CAUTION: Changes or modifications not expressly approved by the party responsible for

compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference in a residential installation. This equip-

ment generates, uses, and can radiate radio frequency energy and, if not installed and used

in accordance with the instruction manual, may cause harmful interference to radio com-

munications. However, there is no guarantee that interference will not occur in a particular

installation. If this equipment does cause harmful interference to radio or television recep-

tion, which can be determined by turning the equipment off and on, the user is encouraged

to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

Importantes Instructions de Sécurité

Wichtige Sicherheitsinstruktionen

Instrucciones de Seguridad Importantes

DECLARATION of CONFORMITY

Crown Audio, Inc.

Sue Whitfield

574-294-8289

[email protected]

european Representative’s Name and address:

David Budge

10 Harvest Close

Yateley GU46 6YS

United Kingdom

equipment Type: Commercial Audio Power Amplifiers
Family Name: CTs
Model Names: CTs 3000, CTs 2000, CTs 1200, CTs 600

eMc Standards:

eN 55103-1:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions
eN 55103-1:1997 Magnetic Field Emissions-Annex A @ 10 cm and 1 M
eN 61000-3-2:1995+a14:2000 Limits for Harmonic Current Emissions (equipment input current £16A per phase)
eN 61000-3-3:1995 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current  £16A
eN 55022:2003 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE: Radiated, Class B Limits; Conducted, Class B
eN 55103-2:1997 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 2: Immunity
eN 61000-4-2:2003 Electrostatic Discharge Immunity (Environment E2-Criteria B, 4k V Contact, 8k V Air Discharge)
eN 61000-4-3:2003 Radiated, Radio-Frequency, Electromagnetic Immunity (Environment E2, criteria A)
eN 61000-4-4:2005 Electrical Fast Transient/Burst Immunity (Criteria B)
eN 61000-4-5:2001 Surge Immunity (Criteria B)
eN 61000-4-6:1996 Immunity to Conducted Disturbances Induced by Radio-Frequency Fields (Criteria A)
eN 61000-4-11:2004 Voltage Dips, Short Interruptions and Voltage Variation

Safety Standard:
eN 60065: 1998
Safety Requirements - Audio Video and Similar Electronic Apparatus
I certify that the product identified above conforms to the requirements of the EMC Council Directive 89/336/EEC as amended by 92/31/EEC, and the Low Voltage Directive 73/23/EES as amended by 93/68/EEC.

Signed

Date of Issue: March 1, 2002

ISSUED BY: Crown Audio, Inc.

1718 W. Mishawaka Road

Elkhart, Indiana 46517 U.S.A.

due to line current harmonics, we recommend that you contact your supply authority before connection.

FOR COMPLIANCE QUESTIONS ONLY:

Andrew Stump

Title: Director of Manufacturing

Advertising