Fig. 3 Bending the

Resistor Leads

To install a resistor, trim the leads
leaving plenty to span the distance
between the sockets and enough to
insert into each socket. Bend the
leads as shown in Figure 3. Be sure
not to bend the leads near the body
of the resistor. Push the leads down
firmly into the sockets. That’s it.

Wiring
Each RPA-RMT has two slide poten-
tiometers. They can be used to con-
trol any two of the four audio inputs on
the P.I.P.-RPA, or they can be ganged
to control more channels. When us-
ing two channels of one amplifier to
feed different rooms, the RPA-RMT
will often be wired to control inputs A
and B, or C and D (see Figure 4).
Here,

PIP inputs A and B are set to

feed the amplifier’s channel 1, and C
and D are set to feed channel 2. This
wiring scheme allows each RPA-RMT
to control a separate room.

The RPA-RMT does not receive any
audio signals. Instead, it receives
10 VDC supplied by the P.I.P.-RPA.
The voltages that return to the

PIP

control its VCAs (Voltage-Controlled
Amplifiers) which control the levels of
the corresponding audio inputs.

Connect the P.I.P.-RPA’s 10 V output
to the RPA-RMT’s +10 V input. Inside
the RPA-RMT, the 10 V signal is fed to
both potentiometers. In turn, the po-
tentiometers control the voltages leav-
ing through the RMT 1 and RMT 2
outputs. Connect these outputs to
any of the four remote inputs on the
P.I.P.-RPA labeled RMT A, B, C or D.

When connecting two remote control
units, run the DC output from the
P.I.P.-RPA in parallel to feed both DC
inputs on the remote units.

When ganging several channels on
one remote slider, run jumper wires
from the remote input on the P.I.P.-

RPA to the other channels being con-
trolled (see the P.I.P.-RPA

Reference

Manual for more details).

Mounting
Mount the RPA-RMT as you would an
AC outlet. Do not mount it in a box
having hot AC! Also, be careful not to
mount it upside down. You can orient
the unit by rotating it until the number
10 on back is at the top and the
number 0 is at the bottom (see Figure
1). Line up the threaded holes in the
receptacle box with the square open-
ings in the RPA-RMT and secure it
with the provided screws.

The RPA-RMT is designed to accept
“designer” series cover plates. Cover
plates are not included because the
provided stick-on labels allow con-
siderable flexibility when choosing
colors to match different interiors.

Labels
Three labels are supplied, each with
a different color scheme: white back-
ground with brown print, ivory back-
ground with brown print and brown
background with ivory print. These
labels match industry standard col-
ors and allow you to select cover
plates to match almost any interior.

Select a stick-on label and affix it to
the remote control faceplate. You can
use the opening in the cover plate as
a guide. Peel the backing and the
plastic front protector from the label
and affix it to the remote unit face-
plate. The last step is to push on the
slider knobs.