Data sheet, Sv01-pl, Functional description – Procom SV01-PL User Manual

Page 2: Voltage supply module for nsa-pl, Block diagram sv01-pl

Advertising
background image



Date:

20.07.2011

Page: 2/3

Author:

VS

Document-No.:

DB_SV01-PL_2104

_

02_en

© 2011 ProCom, All rights and technical changes reserved.

Data Sheet

SV01-PL

Voltage supply module for NSA-PL

Block diagram SV01-PL

KS

48V DC

48V - 72V DC

+5V

GND

SV01-PL

-SV01

(-48V, -60V, -72V)

+SV01

(0V)

BUS

P
C

M

I/O

S

t

e

u

e

r

u

n

g

/

C

o

n

t

r

o

l

Al

On

Anzeige / Indication

-48V




































The DVS-21 slide-in module SV01-PL is part of the ProCom SOS Line concept.
Whenever the 48V DC supply voltage for feeding the SOS line is not sufficient due to cable
length, the SV01-PL module is applied. It converts the nominal supply voltage of 48V DC of
the DVS-21 system into either 48V DC or 60V DC or 72V DC and forwards it towards a NSA-
PL module. At the same time, output and input voltage are isolated galvanically. Thus, it for-
wards a transformed supply voltage towards the WPS-PL call stations. Moreover, it provides
continuous short-circuit protection for the NSA-PL module connected.
The output voltage is set up in using the configuration software ICS.
For monitoring both output voltage and output current of the SV01-PL are measured and the
reading is passed to the processor module. There, as option, it can be evaluated. The vari-
ous operational statuses are displayed on the front plate LEDs.