English – Pfister F-049-VTKK User Manual

Page 5

Advertising
background image

ENGLISH

ENGLISH

14

15

16

CAUTION: Maintenance

DISASSEMBLY
1.

Replacement parts may be available at the store where you purchased
your faucet.

2.

When replacement parts are not available, please write or call Price Pfister
Consumer Service.

3.

Always turn off water and relieve pressure before working on your
faucet.

NOTE: Trim Care

Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp cloth
to clean and shine. Use of polish, detergents, abrasive cleaners,
organic solvents or acid may cause damage. Use of other than
a soft damp cloth will nullify our warranty!
Special Trim:

Trim products which contain Porcelain or other similar substance
are not acceptable for public areas or Commercial use. Installation
of Said Trim is at Users Risk!

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com

• Installation Support
• Care and Warranty Information

14 FAUCET FUNCTION

COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise.

15 FLUSHING & AERATOR CLEANING

After installation is complete, remove Aerator Cartridge (15A) by using Removal Tool
(15B). Turn Valves (15C) on and allow both hot and cold water to run for at least one
minute each. While water is running, check for leaks. Clean Aerator Cartridge (15A).
Once parts have been cleaned, reassemble by reversing steps.

16 VALVE CARTRIDGE REMOVAL

Turn off water supplies and relieve pressure before working on your faucet!
(see step 2). Remove Handles (16A) and Valve Adapter (16B) (see step 7). Unscrew
Retainer Nut (16C) by turning it counter-clockwise and lift out Cartridge Assembly (16D)
and inspect. Replace parts as necessary.

5

OPEN

OPEN

HOT

COLD

16A

16B

16C

16D

15B

15A

15A

15C

Advertising