Truck, Trouble shooting guide, Fig. c wiring diagram – Buyers DBV3500 User Manual

Page 2

Advertising
background image

2

Truck

TM

by

Fig. C Wiring Diagram

Ground

4 AWG

wire

4 AWG

wire

4 AWG wire

16 AWG

wire

16 AWG

wire

cab push button

switch SW900

to ignition switch

power source (fused)

13063171

Solenoid, 12V,

Motor Relay,

Continuous

manual reset

circuit breaker

CB150PB

vibrator

DBV2500/DBV3500

self grounding

through feet

Ground

install and bend lock

tabs as shown

apply medium/strong thread locker

torque to 280 ft. lbs.

Note: For wire lengths

exceeding 50 ft. it is

recommended to use

2 AWG wire.

tabs (as shown in Fig. "C") to prevent bolts from
loosening. Chain vibrator to body for added safety
(chain not included).
6. Wire vibrator per Figure "C" wiring schematic.
7. Install a chassis grounding strap for a more

positive ground. Adequate (4) AWG wire and (2)
additional terminals have been provided for this
purpose.
8. Optional Timer Installation: (Figure "D" or Figure "E")

a. Push button and timer should be mounted in the

cab in a convenient location.

b. The operating time (ON time) of the vibrator is

preset to 15 seconds for the optional timer.

c. To operate: press and release push button. The

vibrator will run for 15 seconds and stop. To run
the vibrator again wait 30 seconds, then press
button again.

d. Wire the timer and push button to truck’s

ignition for secured operation.

TROUBLE SHOOTING GUIDE:

1. Vibrator runs slow: Measure motor voltage. If less

than 12 volts DC, increase wire size from standard 4
AWG to 2 AWG.

Note: Installations requiring over

50’of wire use 2 AWG wire.

Inspect motor brushes and change as needed. Brush
life varies with duty cycle.
2. Loud, unusual vibrator noise: Make sure vibrator

bolts are tight. Inspect mounting plate for cracks.
Reinforce mounting plate and weld as needed. If
vibrator casting is cracked replace with new parts.
3. Vibrator fails to operate: Check vibrator to

make sure it is getting power. Check all electrical
connections (and ground) for secure corrosion free
connections. Vibrator is grounded through its foot.
Install grounding strap for a more positive ground.
Check cab push button switch, solenoid and circuit
breaker for proper operation. Note: 150 Amp circuit
breaker requires manual reset. If tripped, reset.
Maximum continuous run time is 15 seconds followed
by 30 seconds cooling time before operating again.
NOTE: Although the vibrator has o-ring seals and
the bearings are permanently lubricated, avoid
spraying vibrator directly with water and do not

pressure wash.

Optional 3011111

Timer Diagram

Optional 3022840

Timer Diagram

Fig. D

Fig. E

4 AWG

wire

16 AWG

wire

cab push button

switch SW900

Timer

3011111

to ignition switch

controlled power source

Ground

(-) GROUND

INITIION SWITCH CONTROL

POWER SOURCE (+)

16 AWG WIRE

CAB PUSH BUTTON

SWITCH SW900

12 V SOLENOID MOTOR RELAY

TIMER 3022840

see Fig D or E for

optional timer

installation

Advertising