Littelfuse CBO Series User Manual

Special purpose fuses, Fork-lift and stud-mounted fuses, Specifications

Advertising
background image

Special Purpose Fuses

107

w w w . l i t t e l f u s e . c o m

Sp

ec

ia

l P

ur

po

se

Fu

se

s

© 2005 Littelfuse

POWR-GARD

Products Catalog

Fork-Lift and Stud-Mounted Fuses

32 – 130 Volts DC • Fast Acting and Time-Delay

Part No.

A

B

C

CCK 1-15A

2.810

2.204

0.510

CCK 20-30A

3.060

2.454

0.510

CCK 35-60A

3.629

0.750

CCK 70-120A

4.129

3.454

1.00

CCK 140-200A

4.362

3.579

1.00

CCK 225-300A

4.612

3.829

1.00

CCL 30-60A

3.060

2.454

0.51

CCL 80-120A

3.38

2.70

0.75

3.18"

0.343"

2.43"

0.812"

1.00"

1.625"

A
B

C

3.18"

0.343"

2.43"

CCK/CCL

CBO

CNL/CNN Limiter Fuses

Specifications

Voltage Ratings:

CNL: 32 Volts DC

CNN: 48 Volts DC, 75 Volts AC

Interrupting Rating:

2,500 amperes

Ampere Range:

10 – 800 amperes

Maximum Torque:

90 Inch lbs.

Recommended Fuse Block

LFFB001

Ampere ratings

CNL

35

80

150

250

350

40

100

175

275

400

50

125

200

300

500

60

130

225

325

CNN

10

80

175

300

500

35

90

200

325

600

40

100

225

350

700

50

125

250

400

800

60

150

275

Example part number (series & amperage): CNN 700

CBO/CCK/CCL Lift-Truck Fuses

CBO fast acting, and CCK and CCL dual-element time-delay fuses are rec-
ommended for fork lift trucks and other similar battery operated equipment.

Specifications

Voltage Ratings:

CBO: 32 Volts DC

CCK: 130 Volts DC (1-100A)

72 Volts DC (120-200A)

48 Volts DC (225-300A)

CCL: 125 Volts DC

Interrupting Rating:

CBO, CCK & CCL: 10,000A

Ampere Range:

1 – 300 amperes

For operating characteristics contact factory

Ampere ratings

CBO

10

25

50

80

Fast Acting

12

30

60

100

15

35

70

125

20

40

75

150

CCK

1

25

60

120

200

Time-Delay

2

30

70

140

225

10

35

75

150

250

15

40

80

160

300

20

50

100

175

CCL

30

40

60

100

Time-Delay

35

50

80

120

Example part number (series & amperage): CCK 150

CNL fast-acting and CNN very fast acting fuses are recommended for
use on battery operated lift trucks and other low voltage battery operated
equipment.

Advertising