Littelfuse Battrax Series MS-013 Singl Port Negative User Manual

Sidactor, Protection thyristors, Battrax

Advertising
background image

SIDACtor

®

Protection Thyristors

118

Revised: September 30, 2011

© 2011 Littelfuse, Inc.

Specifications are subject to change without notice.

Please refer to www.littelfuse.com for current information.

SLIC Protection

Battrax

®

Series - Single Port Negative -

MS-013

1

3

2

5

(T)

(-V

REF

)

(R)

(G)

6

(No Connect)

4

(No Connect)

Electrical Characteristics

The Battrax

®

series offers programmable SIDACtor

®

overvoltage protection devices for SLIC applications.
The Single Port Negative Battrax Series provides a
programmable device that is referenced to a negative
voltage souce while internal diodes provide protection
from positive surge events.

Description

Agency Approvals

Agency

Agency File Number

E133083

Schematic Symbol

Pinout Designation

Features and Benefits

• Low voltage overshoot
• Low on-state voltage
• Does not degrade with

use

• Fails short circuit when

surged in excess of
ratings

• Single-port protection
• Gate triggered tracking

device

• Integrated diodes for

positive voltage

Part Number

Marking

V

DRM

@l

DRM

=5µA

V

S

@100V/µs

I

H

I

S

I

T

V

T

@I

T

=2.2 Amps

V

F

Capacitance*

V min

V max

mA min mA max

A max

V max

V max

pF min pF max

B1101UALxx

B1101UA I-V

REF

I + I-1.2VI I-V

REF

I + I-10VI

100

100

2.2

4

5

30

200

B1161UALxx

B1161UA I-V

REF

I + I-1.2VI I-V

REF

I + I-10VI

160

100

2.2

4

5

30

200

B1201UALxx

B1201UA I-V

REF

I + I-1.2VI I-V

REF

I + I-10VI

200

100

2.2

4

5

30

200

B1101UCLxx

B1101UC I-V

REF

I + I-1.2VI I-V

REF

I + I-10VI

100

100

2.2

4

5

30

200

B1161UCLxx

B1161UC I-V

REF

I + I-1.2VI I-V

REF

I + I-10VI

160

100

2.2

4

5

30

200

B1201UCLxx

B1201UC I-V

REF

I + I-1.2VI I-V

REF

I + I-10VI

200

100

2.2

4

5

30

200

1

2

3

6

5

4

Applicable Global Standards

• TIA-968-A
• TIA-968-B
• ITU K.20/21 Enhanced

Level

• ITU K.20/21 Basic Level
• GR 1089 Inter-building

• GR 1089 Intra-building
• IEC 61000-4-5
• YD/T 1082
• YD/T 993
• YD/T 950

Notes:

- Absolute maximum ratings measured at T

A

= 25ºC (unless otherwise noted).

- Devices are uni-directional
- All electrical characteristics shown are defined from Tip (pin 1) to Ground (pin 5), and Ring

(pin 3) to Ground (pin 5)

- V

REF

Max Value for the negative Battrax is -200 V.

- XX = Part Number Suffix: ‘TP’ (Tube Pack) or ‘RP’ (Reel Pack).
* Off-state capacitance (C

O

) is measured across pins 1 & 5 and 3 & 5

at 1 MHz with a 2V bias.

Advertising