Littelfuse 223 Series User Manual

5 x 20 mm, Axial lead and cartridge fuses, Designed to iec standard

Advertising
background image

Designed to IEC Standard

Axial Lead and Cartridge Fuses

5 x 20 mm

Time Lag Fuse (Slo-Blo

®

Fuse) 218/213 Series

295

w w w . l i t t e l f u s e . c o m

8

AXIAL LEAD AND

CAR

TRIDGE FUSES

10A

15A

8A

6.3A

5A

4A

3.15A

2.5A

2A

1.6A

1.25A

1A

.800A

.630A

.500A

.400A

.315A

.250A

.200A

.160A

.125A

.100A

.080A

.063A

.050A

.040A

.032A

500

100

10

1

0.1

0.05

0.001

0.01

0.1

1

10

100

TIME IN SECONDS

CURRENT IN AMPERES

Average Time Current Curves for 218/228

• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 3 specification for Time Lag Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.032 to 10 amperes.

ELECTRICAL CHARACTERISTICS:

% of Ampere

Ampere

Opening

Rating

Rating

Time

150%

.032 – .100

60 minutes, Minimum

.125 – 6.3

60 minutes, Minimum

210%

.032 – .100

2 minutes, Maximum

.125 – 6.3

2 minutes, Maximum

275%

.032 – .100

0.2 sec., Min.; 10 sec. Max.

.125 – 6.3

0.6 sec., Min.; 10 sec. Max.

400%

.032 – .100

.04 sec., Min.; 3 sec. Max.

.125 – 6.3

.15 sec., Min.; 3 sec. Max.

1000%

.032 – .100

.01 sec., Min.; 0.3 sec. Max.

.125 – 6.3

0.02 sec., Min.; 0.3 sec. Max.

AGENCY APPROVALS:

Sheet III IEC 60127-2:* SEMKO, VDE

approved thru 6.3 amps. BSI approved 0.08-6.3 amps. Recognized under
the Components Program of Underwriters Laboratories and recognized
by CSA. 0213 series METI approved 1-5A.

VOLTAGE RATING:

250 VAC

INTERRUPTING RATINGS:

35 amperes or 10 x rated current;

whichever is greater.

ORDERING INFORMATION:

For axial leaded change 218 to 228 and 213 to 223.

218/228

213/223 Surge Withstand

Cartridge

Nominal

Nominal

Cartridge

Nominal

Nominal

Ampere

Catalog

Resistance

Melting I

2

t

Catalog

Resistance

Melting

Rating

Number

Cold Ohmns

A

2

Sec.

Number

Cold Ohms

I

2

t A

2

Sec.

.032

218.032

58.45

0.00305

.040

218.040

35.70

0.0055

.050

218.050

23.30

0.0071

.063

218.063

18.1

0.012

.080

218.080

12.6

0.0265

.100

218.100

8.95

0.0495

.125

218.125

4.41

0.150

.160

218.160

2.44

0.225

.200

218.200

1.60

0.350

0213.200

1.60

0.350

.250

218.250

1.05

0.555

0213.250

1.05

0.555

.315

218.315

0.848

1.14

0213.315

0.848

1.14

.400

218.400

0.535

1.35

0213.400

0.535

1.35

.500

218.500

0.370

2.90

0213.500

0.370

2.90

.630

218.630

0.275

4.80

0213.630

0.275

4.80

.800

218.800

0.073

1.99

0213.800

0.165

9.42

1

218 001

0.055

3.33

0213 001.

0.117

19.20

1.25

218 1.25

0.042

5.80

0213 1.25

0.081

27.15

1.6

218 01.6

0.032

10.61

0213 01.6

0.055

44.2

2

218 002

0.029

14.80

0213 002.

0.044

92.7

2.5

218 02.5

0.022

23.85

0213 02.5

0.030

138.0

3.15

218 3.15

0.017

39.20

0213 3.15

0.022

226.5

4

218 004

0.013

70.95

0213 004.

0.017

202

5

218 005

0.010

114.0

0213 005.

0.011

314

6.3

218 06.3

0.0075

204.0

0213 06.3

0.008

600

8

218 008

0.0059

350.5

10

218 010

0.0045

583.0

15

218 015

0.0030

1441.0

*

IEC Standards for 5 x 20 fuses do not include ratings above 6.3A, but are
under consideration.

5

(.197")

5.25

(.207")

40

(1.58")

.635

(.025")

20

(.787")

22.5 MAX

(.886)

Please contact Littelfuse for Average Time Current Curve
for 213/223 surge withstand.

1

228 and 223 Series are used for North American ordering.

®

®

V

D

E

213 000 XE
223
000
218 000 XE
228
000

213 000

218 000

Next

Previous

Advertising