For ATO

®

Fuses

In-Line Type

SPECIFICATIONS:
Electrical:

Intended for use with 32 volts Autofuse

®

fuses rated to 20 or

30 amperes depending on wire size and terminal combinations.

Mounting:

Capable of snap-mounting to panel from rear. Fuseholders

interlock for multiple mounting.

Molded Parts:

Black Thermoplastic (UL 94V2).

Terminals:

Brass. Tin-plated. Snap-lock into body.

Ambient Temperature:

– 40°C to +85°C.

Wire:

Stranded with PVC insulation, black #14 AWG for 155 300 Series

and orange #10 AWG for 155 400 Series.

PATENTED
ORDERING INFORMATION:

Catalog Number

Assembled with

Assembled with

Fuse

8" Wire Loop,

8" Wire Loop

Amperage

Unassembled

No Fuse

and Fuse

Rating

155 320U

155 300

155 303A

3

(Terminals designed

(#14 wire/

155 304A

4

for #14 AWG

terminals rated

155 305A

5

stranded wire and

to 20A).

155 37.5A

7.5

marked “14”).

155 310A

10

155 315A

15

155 320A

20

155 430U

155 400

155 425A

25

(Terminals designed

(#10 wire/

155 430A

30

for #10 AWG

terminals rated

stranded wire and

to 30A).

marked “10”).

UNASSEMBLED

For MINI

®

Fuses

In-Line Type — Easy Crimp Fuseholder

SPECIFICATIONS:
Terminals:

Copper Alloy/Tin plated.

Body:

Black Thermoplastic.

Operating Temperature:

– 40°C to +105°C.

Use standard crimping tool and crimp the matted area to secure wire.
(Possible crimp tool - Ideal #30-428 [Toothed Die slot] or equivalent).

ORDERING INFORMATION:

For ATO

®

Fuses

P.C. Board Mount Type

SPECIFICATIONS:
Electrical:

Intended for use with 32 volts ATO

®

fuses rated to 15

amperes.

Molded Parts:

Black Thermoplastic

Terminals:

Copper Alloy, Tin Plated

Ambient Temperature:

– 40°C to +85°C

.

ORDERING INFORMATION:

Catalog Number: 04450715

Catalog

Number

Description

153 002

20A Max. Rating — Terminals will accept #16 – 22 AWG (1.0-
.33 mm

2

) stranded wire (use appropriate wire size based on

fuse usage). For example — Use #16 AWG wire for 20A fuse.

153 003

30A Max. Rating — Terminals will accept #10– 14 AWG (5.0-
2.0 mm

2

) stranded wire (use appropriate wire size based on

fuse usage). For example — Use #10 AWG wire for 30A fuse.

Typical Multiple Mounting
(Fuseholders interlocked)

Recommended Panel Mounting Hole
(.04" / .078" thick panel)

10.16

(.40")

37.08

(1.46")

30.48 (1.20")

24.64

(.970")

19.05 (.75")

10.54 (.415")

10.41 (.410")

27.94 (1.10")
26.92 (1.06")

.254 (.01") R. Max.

Add .400" to width for each additional fuseholder

Tool For Fuse Removal or Replacement; Part No. 097024.

MATTED

(CRIMP) AREA

11.43

(.45")

END VIEW

17.02
(.67")

52.58

(2.07") Max

SIDE VIEW

6.35 (.25")

17.02 (.67")

9.3

(.366")

21.8

(.858")

9.3

(.366")

2.5

(.098")

4.5

(.177") Ref.

9

(.354")

22

(.866")

* Please refer to Fuseology section for information on proper fuseholder de-rating.