background image

GB

17

regulation screw must be fastened as tightly as
possible.

5. Turn

the knob from the MAX position to the MIN position
quickly or open and shut the oven door, making sure
that the burner is not extinguished.

! Be careful of the spark plug wires and the
thermocouple tubes.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
“regulators for channelled gas”.

Table of burner and nozzle specifications

S

S

R

A

CG64SG1 I /HA
CG64SG1 X I /HA
CG64SG1 AG /HA
CG64SG1 X AG /HA

TECHNICAL DATA

Oven Dimensions
HxWxD

31x43,5x43,5 cm

Volume

58 l

Useful
measurements
relating to the
oven compartment

width 46 cm

depth 42 cm

height 8,5 cm

Voltage and
frequency

see data plate

Burners

may be adapted for use with any

type of gas shown on the data

plate.

EC Directives 2006/95/EC dated

12/12/06 (Low Voltage) and

subsequent amendments -

04/108/EC dated 15/12/04

(Electromagnetic Compatibility)

and subsequent amendments -

2009/142/EC dated 30/11/09 (Gas)

and subsequent amendments -

90/68/EEC dated 22/07/93 and

subsequent amendments. -

2002/96/EC.

1275/2008(Stand-by/Off-mode)

Table 1

Liquid gas

Natural gas

Diameter

(mm)

Thermal power

kW (p.c.s.*)

By Pass

1/100

Nozzle

1/100

capacity*

g/h

Nozzle

1/100

capacity *

l/h

Burner

Nomin.

Red.

(mm)

(mm)

***

**

(mm)

Rapid (R)

100

3.00

0.70

41

86

218

214

116

286

Semi-rapid (S)

75

1.90

0.40

30

70

138

136

106

181

Auxiliary (A)

55

1.00

0.40

30

50

73

71

79

95

Oven

-

2.60

1.00

52

78

189

186

119

248

Supply
pressure

Nominal (mbar)

Minimal (mbar)

Maximised (mbar)

28-30

20
35

37
25
45

20
17
25

*

At 15°C and 1013 mbar - dry gas

**

Propane P.C.S. = 50.37 MJ/Kg

***

Butane P.C.S. = 49.47 MJ/Kg

Natural P.C.S. = 37.78 MJ/m³