Littelfuse 389 Series User Manual

Axial lead & cartridge fuses, 389 series, Time lag > 389 series

Advertising
background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.
Revised: 12/19/13

Axial Lead & Cartridge Fuses

TE5

®

>Time Lag > 389 Series

Features

Electrical Characteristics

Applications

Electrical Characteristics

Agency Approvals

Agency

Agency File Number

Ampere Range

60mA

389 Series

• For worldwide

applications

• Reduced PCB space

requirements

• Highly defined cut-off

times

• Irreversible physical

separation

• Low internal resistance
• Flame resistant

encapsulated casing

• RoHS compliant and

Lead-free

• Available for 60MA only

% of Ampere

Rating

Opening Time

166

600 ms, Min.

250

45 ms, Max.

Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand.

Continous

Current I

C

Type

Amp Code

Voltage

Rating

Fault Current max.

Cold

Resistance

0.1 x I

C

typ.

(mΩ)

power

Dissipation

1.0 x I

C

max.

(mW)

melting
Integral

10 x I

C

typ.

(A

2

s)

60mA

0060

250 VAC

10A / 250VAC/DC

50-60 Hz cos ϕ = 1.0

80

100

0.033

The 389 Series are TR5

®

, time-lag type, 250V rated fuses.

For Short Circuit Protection of Sensitive
Electronic Components and Assemblies

• Telecom equipment
• Data processing

equipment

• Input/output modules

• Household appliances
• Medical equipment

Description

Additional Information

Datasheet

Samples

Resources

Advertising