Littelfuse 2016L Series User Manual

Poly-fuse, Resettable ptcs, 2016l series

Advertising
background image

45

Revised: March 19, 2012

POLY-FUSE

®

Resettable PTCs

© 2012 Littelfuse, Inc

20

16L S

eries

Surface Mount > 2016L Series

2016L Series

Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/2016L.html for current information.

2016L Series

The 2016L Series PTC provides surface mount overcurrent
protection for low voltage (≤60V) applications where
resettable protection is desired.

Electrical Characteristics

Part Number

Marking

I

hold

(A)

I

trip

(A)

V

max

(Vdc)

I

max

(A)

P

d

typ.

(W)

Maximum Time

To Trip

Resistance

Agency

Approvals

Current

(A)

Time

(Sec.)

R

min

(Ω)

R

typ

(Ω)

R

1max

(Ω)

2016L030

LF030

0.30

0.60

60

20

1.40

1.5

3.0

0.500

1.40

2.30

X

X

2016L050

LF050

0.55

1.10

60

20

1.40

2.5

5.0

0.200

0.70

1.00

X

X

2016L075/60

LF075-60

0.75

1.50

60

20

1.40

8.0

0.5

0.130

0.50

0.90

*

*

2016L100

LF100

1.10

2.20

15

40

1.40

8.0

0.5

0.100

0.25

0.40

X

X

2016L100/33

LF100-33

1.10

2.20

33

40

1.40

8.0

0.5

0.100

0.25

0.40

X

X

2016L150

LF150

1.50

3.00

15

40

1.40

8.0

1.0

0.070

0.13

0.18

X

X

2016L200

LF200

2.00

4.20

6

40

1.40

8.0

3.0

0.048

0.07

0.10

X

X

I

hold

= Hold current: maximum current device will pass without tripping in 20°C still air.

I

trip

= Trip current: minimum current at which the device will trip in 20°C still air.

V

max

= Maximum voltage device can withstand without damage at rated current (I max)

I

max

= Maximum fault current device can withstand without damage at rated voltage (V

max

)

P

d

= Power dissipated from device when in the tripped state at 20°C still air.

R

min

= Minimum resistance of device in initial (un-soldered) state.

R

typ

= Typical resistance of device in initial (un-soldered) state.

R

1max

= Maximum resistance of device at 20°C measured one hour after tripping or reflow soldering of 260°C for 20 sec.

Caution: Operation beyond the specified rating may result in damage and possible arcing and flame.

* Agency Approval is Pending

Description

Features

Applications

t3P)4DPNQMJBOU MFBEGSFF

and halogen-free

t'BTUSFTQPOTFUPGBVMU

currents

t)JHIWPMUBHF
t-PXQSPmMF

t*&&QPSUQSPUFDUJPO
t1PXFSFEFUIFSOFUQPSU

QSPUFDUJPO *&&&BG 

t"VUPNPUJWFFMFDUSPOJD

control module protection

t-PXWPMUBHFUFMFDPN

equipment protection

Agency Approvals

AGENCY

AGENCY FILE NUMBER

E183209

R50119118

Advertising