Littelfuse 400 Series User Manual

Radial lead fuses, 400 series, te5, Time-lag fuse

Advertising
background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.
Revised: 12/19/13

Radial Lead Fuses

TE5

®

> Time-Lag > 400 Series

400 Series, TE5

®

, Time-Lag Fuse

Agency Approvals

Agency

Agency File Number

Ampere Range

E67006

800mA – 6.3A

JET1896-31007-2001

JET1896-31007-1003

1A – 5A

6.3A

DE1-40597

500mA – 6.3A

CQC09012031624

500mA – 6.3A

SUS05024-9004

500mA – 800mA

SUS05024-9003

1A – 2.5A

SUS05024-9001

3.15A

SUS05024-10003

4A – 5A

SUS05024-9002

6.3A

Features

Electrical Characteristics

• Lead-free and RoHS

Compliant

• Reduced PCB space

requirements

• Direct solderable or plug-

in versions

• Low internal resistance
• Shock safe casing
• Vibration resistant
• Halogen-free

% of Ampere

Rating

Opening Time

150%

1 Hour, Minimum

210%

120 Secs., Maximum

275%

400 ms, Minimum; 10 Secs., Maximum

400%

150 ms, Minimum; 3 Secs., Maximum

1000%

20 ms, Minimum; 150 ms, Maximum

Electrical Characteristics

Amp

Code

Rated

Current

Rated

Voltage

breaking Capacity

Voltage

Drop

1.0×I

N

max. (mV)

power

Dissipation

1.0×I

N

max. (mW)

melting
Integral

10×I

N

max. (A

2

s)

Agency Approvals

0500

500mA

250V

130A/250VAC*

50-60 Hz cos

ϕ

= 1.0

165

297

2.17

x

x

x

x

0800

800mA

250V

116

387

6.72

x

x

x

x

1100

1.00A

250V

89

432

9.63

x

x

x

x

x

1125

1.25A

250V

76

411

14.44

x

x

x

x

x

1160

1.60A

250V

76

601

21.75

x

x

x

x

x

1200

2.00A

250V

75

758

32.16

x

x

x

x

x

1250

2.50A

250V

61

683

61.94

x

x

x

x

x

1315

3.15A

250V

55

921

101.61

x

x

x

x

x

1400

4.00A

250V

65

936

133.40

x

x

x

x

x

1500

5.00A

250V

56

948

216.50

x

x

x

x

x

1630

6.30A

250V

48

926

318.71

x

x

x

x

x

* Per VDE, approved breaking capacity is at 100A, 250VAC

The 400 Series is a TE5

®

, Time-Lag type subminiature fuse

designed for overcurrent protection. It is 250V rated and
designed in accordance to IEC 60127-3.

Description

Applications

• Battery chargers
• Consumer electronics

• Power supplies
• Industrial controllers

Additional Information

Datasheet

Samples

Resources

Advertising