Ceramic Fuse > 501 Series

501 Series – High Current 1206 Fast-Acting Fuse

Description

The 501 Series is a 100% Lead-free, RoHS compliant and
Halogen-free fuse series designed specifically to provide
over- current protection to circuits that operate under high
working ambient temperature up to 150°C.
The general design ensures excellent temperature stability
and performance reliability.
The high I

2

t values which is typical in the Littelfuse

Ceramic Fuse family, ensure high inrush current withstand
capability.

Agency Approvals

AgeNCy

AgeNCy FIle NumbeR

AmpeRe RANge

e10480

10A - 20A

lR29862

10A - 20A

Features

• Operating Temperature

from -55ºC to +150ºC

• Designed to provide

over-current protection
in high current voltage
regulator module (VRM)
applications

• 100% Lead-free, RoHS

compliant and Halogen-
free

• Suitable for both leaded

and lead-free reflow /
wave soldering

Electrical Characteristics for Series

% of Ampere

Rating

Ampere Rating

Opening Time at 25ºC

100%

10A – 20A

4 Hours, Minimum

350%

10A – 20A

5 Seconds, Maximum

Applications

• Voltage Regulator

Module (VRM)
Equipment

• Notebook PC
• DC-DC Converter

Ampere

Rating

(A)

Amp

Code

max. Voltage

Rating

(V)

Interrupting

Rating

(DC)

1

Nominal

Resistance

(Ohms)

2

Nominal

melting I

2

T

(A

2

Sec.)

3

Nominal Voltage

Drop At Rated

Current (V)

4

Nominal power

Dissipation At

Rated Current (W)

Agency Approvals

10

010.

32

150 A @ 32 VDC

0.00427

10.385

0.05679

0.5679

x

x

12

012.

32

0.00321

20.341

0.04891

0.5870

x

x

15

015.

32

0.00250

36.100

0.04605

0.6908

x

x

20

020.

32

0.00200

54.760

0.05936

1.1871

x

x

Electrical Specifications by Item

Notes:
1. DC Interrupting Rating tested at rated voltage with time constant < 0.5 msec.
2. Nominal Resistance measured with < 10% rated current.
3. Nominal Melting I

2

t measured at 1 msec. opening time. For other I

2

t data refer to chart.

4. Nominal Voltage Drop measured at rated current after temperature has stabilized and

with fuse mounted on board with 3-oz Cu trace.

Devices designed to carry rated current for 4 hours minimum. It is recommended that
devices be operated continuously at no more than 80% rated current. See “Temperature
Rerating Curve”for additional rerating information.

Devices designed to be mounted with marking code facing up.

Additional Information