Littelfuse T4900 Series User Manual

T4900 series, Generator control, Basic

Advertising
background image

Generator Control

© 2013 Littelfuse Protection Relays & Controls

Features

BeNeFIts

Adjustable delta voltage,

stability and % VAR load

deviation by front panel

potentiometers

Facilitates adjustment during installation and

commissioning. VAR Load deviation adjustment

enables paralleling of differenst size generators

Inputs for disabling internal

voltage control

Enables operation where system voltage is set

externally such as in grid-parallel operation

Power factor control

function

Enabling alternative use as power factor

controller, thus maintaining fixed power factor

(cos phi) in installations with fluctuating

inductive loads

Visual indication of voltage,

increase/decrease and

unload signals

Provides quick and concise status information

Direct line-line voltage

supply (up to 690 Vac)

Simplifies design and installation. No need for

PTs or separate power supply

Galvanic isolated inputs

Protects the unit against high AC voltage and

currents from the installation including spikes

DIN-rail or screw mount

Easy installation

Basic

t4900 serIes

VAR Load Sharer

Description

The T4900 VAR Load Sharer provides automatic load sharing

of reactive power [kVAR] and voltage control for parallel

running generators. The reactive load on each generator is

compared with the reactive load on the other generators

and corrected on the AVR (Automatic Voltage Regulator)

until balance is obtained. The T4900 can also be used for

power factor (PF) control in applications where one or more

generators are operated in parallel with the grid (utility). The

input to the T4900 are the voltage and the current from which

the reactive power and voltage is determined. The T4900

calculates I x sin φ, representing the reactive load.
Power factor control for parallel operation with the public

grid can be obtained by connecting an external contact

between terminals 12 (COM) and 28 (PF ON). The setting is

determined by an external potentiometer (100 kW) across

terminals 29 and 30 (PF-SET).

Simplified Circuit Diagram

Features & Benefits

Other supply voltages, nominal currents and combinations are available on request.

Specifications

Max. Voltage

660 V

Voltage Range

110%

Voltage Dev. Adjustment 0- ±12 V

Consumption

Voltage 4 VA at U

N

Current 0.4VA at I

N

Continuous Current

2 x I

N

Frequency Range

35-70 Hz

Proportional Band

±25-125% load

Dead Band Zone

±1-10% load

Contact Rating

AC: 400 V, 2 A, 250 VA; DC: 110 V, 2 A, 100 W

Operating Temperature –20°C to +70°C

EMC

CE according to EN50081-1, EN50082-1,

EN50081-2, EN50082-2

Burn-in

50 hours before final test

Enclosure Material

Polycarbonate, flame retardant

Weight

0.7 kg

Dimensions

H 70 mm (2.7“); W 150 mm (5.9“); D 115 mm (4.5“)

Installation

35 mm DIN rail or 4 mm (

3

/

16

”) screws

www.littelfuse.com/t4900

OrderINg NumBer

termINals

I

N

1-3

2-3

T4900.0010

450 V

400 V

5 A

T4900.0020

230 V

5 A

T4900.0030

480 V

415 V

5 A

T4900.0040

110 V

63 V

5 A

T4900.0050

127 V

120 V

1 A

T4900.0060

110 V

100 V

1 A

Ordering Information

BUS

U

N

I

N

GEN

AVR

M

1

2

3

4

5

6

7

8

9

10

11

12

12

12

1

2

3

4
5
6

13

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30 31

32

L

1

L

2

L

3

UNLOAD

UNLOAD or

PF=1.0

PF=1.0 – 0.7 ind.

100 K

NEXT
T4900

E7800

(Motorized

Potentiometer)

COM.

PARALLEL

LINES

INCR. DECR.

POWER FACTOR

VOLT

OUT

VOLT

IN

PF–SET.

PF ON

TRIP ENABLE

WATT

IN

TEST

OUT

+

T4900

(VAR Load Sharer)

T4910-07 Potentiometer with Cable for

External Power Factor Setting

External contact between terminals

12 (COM) and 28 (PF ON). Included.

Accessories

A

A

Rev: 4-A-050313