Littelfuse PGR-4700 Series User Manual

Powr-gard, Protection relays, monitors & systems, Sensitive ground-fault relay description

Advertising
background image

© 2009 Littelfuse

POWR-GARD

®

Protection Relay Catalog

12

POWR-GARD

®

Protection Relays, Monitors & Systems

G

rO

u

ND

-F

A

u

lT

P

rO

TE

CT

IO

N

r

El

AY

S

www.littelfuse.com/series/PGR-4700.html

Ground-Fault Protection – Solidly Grounded System (PGr 4000 Family)

PGr-4700 SerIeS (rCD300M2)

Sensitive Ground-Fault Relay

Description

The PGR-4700 Sensitive Ground-Fault Relay provides
sensitive ground-fault protection without nuisance tripping.
It detects very low-level leakage current on large circuits
to avoid or significantly reduce equipment damage. The
leakages can be identified as they develop and ground faults
can be detected before they become critical.

Applications

Ground-fault relays can be used for the protection of critical
circuits in panel boards and switch boards, OEM power
distribution panels and custom controls. They are typically
used in critical load applications with costly downtime and
hazards, such as high humidity, water, dust, chemicals, and
vibration.

Features/Benefits

Adjustable trip level settings from 10 mA to 3.0 A

Advanced harmonic filtering

Compatible with VFD applications

Adjustable time delay

Metering output with PLC interface for continuous

monitoring of system
CT loop monitoring

Ordering Information

Specifications

IEEE Device Numbers

50G, 50N, 51G, 51N

Input Voltage

See Ordering Information

Dimensions

H 75 mm (3.0”); W 55 mm (2.2”); D 115 mm (4.5”)

Trip level Settings

10 mA – 3.0 A

Trip Time Delay Settings

0–1.5 s

Contact Operating Mode

Selectable fail-safe or non-fail-safe

(Internal switch)

Harmonic Filtering

Standard

Test Button

Standard

reset Button

Standard

CT loop Monitoring

Standard

relay Contacts

2 N.O. and N.C.

Approvals

UL listed

Communications

Analog Output

Conformally Coated

Optional

Warranty

5 Year

Mounting

DIN, Surface

TEST RESET

CONTROL

POWER

+

SENSITIVE GROUND-FAULT RELAY
PGR-4700 SERIES

POWR-GARD

®

ANALOG

OUTPUT

GROUND FAULT

0-1mA

PGC 5000
SERIES

POWR-GARD

®

GROUND-FAULT

CURRENT

TRANSFORMER

PGA-0500

POWR-GARD

®

ANALOG %
CURRENT METER

(optional)

1

2

4

5

6

7

8

9

10 11 12 13 14 15

16

PGR-4700-24

24 Vdc Control Power

PGR-4700-120

120 Vac Control Power

PGR-4700-240

240 Vac Control Power

See pg. 31-36 for Current Transformer Selection Guide and

Accessory Information.

Advertising