Littelfuse FLR569 Boxed_Carded User Manual

18 flashers

Advertising
background image

FLASHERS

Type of Load
Variable vs. Exact:
• Variable load flashers will handle a range of lamps as needed up to the total specified.
• Exact load flashers will flash only the number of lamps for which it is rated. These are typically for OEM

replacement applications.

Lamp Capacity
The total number of lamps energized in the circuit.
Terminal Count
Two or three terminals — always match the terminal configuration being replaced.
Design
Thermal vs. Electronic:
• Thermal (Bi-Metal) flashers are a mechanical device that operate through the heating and cooling of a

bi-metal strip, opening and closing the contacts, causing the lamps to “flash”.

• Electronic flashers are comprised of an electro-mechanical relay with an opposing A and B coil. A

capacitor prevents one coil from pulling in relay contacts until it is fully charged. The charging and dis-
charging of the capacitor along with a resistor determine the flash rate and set duty cycle (on/off time).

In some cases you can replace a Thermal Flasher with an Electronic Flasher but never replace an
Electronic Flasher with a Thermal Flasher.

THERMAL FLASHERS

Universal Variable For Domestic Cars

Universal design replaces most popular part numbers 536 and 552.
• Replaces 12-volt, two terminal flashers.
Capacity

– Turn Signals: Flashes two to three 32 C.P. standard or long-life lamps.
– Hazard Warning: Flashes two to six lamps.

• Features durable, heavy duty thermal flashing mechanism for increased reliability.
• Quality construction ensures continued operation even under harsh temperature and

humidity environmental factors.

18 FLASHERS

Littelfuse Flashers meet D.O.T., S.A.E. and all applicable state and federal requirements.

Bulk

Part No.

FLR 536/552

US

Carded No.

FLR 536/552 BP

Canadian

Carded No.

FLR 536/552 CABP

Volts

12

Terminals

2

Lamps

2 – 6

Variable For Import Cars/Domestic Trucks

• Replaces most 12 volt, three terminal flashers.
Capacity

– Turn Signals: Flashes two to three 32 C.P. standard or long-life lamps.
– Hazard Warning: Flashes two to six lamps.

• Separate pilot circuit and durable, heavy duty thermal flashing mechanism for

increased reliability.

• Quality construction ensures continued operation even under harsh temperature

and humidity environmental factors.

Bulk

Part No.

FLR 550

US

Carded No.

FLR 550 BP

Canadian

Carded No.

FLR 550 CABP

Volts

12

Terminals

3

Lamps

2 – 6

Variable For Cars and Light Trucks

• Replaces 12 volt, three terminal flashers.
Capacity

– Turn Signals: Flashes two to three 32 C.P. standard or long-life lamps.
– Hazard Warning: Flashes two to six lamps.

• Features durable, heavy duty thermal flashing mechanism for increased reliability.
• Quality construction ensures continued operation even under harsh temperature and

humidity environmental factors.

Bulk

Part No.

FLR 569

US

Carded No.

FLR 569 BP

Canadian

Carded No.

FLR 569 CABP

Volts

12

Terminals

3

Lamps

2 – 6

Pin Configuration Key

-

+

X = Battery

L = Lamp

P = Pilot Light

Advertising