Littelfuse FLSR_ID Series User Manual

Class rk5 – flnr_id • flsr_id series indicator, Fuses, Powr-gard

Advertising
background image

POWR-GARD

®

Fuse Datasheet

© 2014 Littelfuse POWR-GARD

®

Products

Rev: 020614

littelfuse.com

1 of 2

Class RK5 – FlNR_ID • FlsR_ID sERIEs INDICatoR

®

FUsEs

250/600 Vac • Dual Element • Time Delay •

1

/

10

-600 A

Description

Available in both Indicating and Non-Indicating versions,
the FLNR/FLSR series of fuses set the standard for general
purpose fuses. The dual-element design provides advanced
short circuit and overload protection. FLSR series fuses
provide excellent protection for all types of circuits especially
those containing motors.

Applications

• Service entrance switches
• Switchboard mains and feeders
• Motor control central mains and motor branch circuits
• All general purpose circuits

Features/Benefits

• Indication
• Dual-element design
• Available without indication
• Current limiting

Specifications

Voltage Ratings

AC: 250 V (FLNR_ID); 600 V (FLSR_ID)

DC: 125 V (FLNR

1

/

10

– 30 A);

125 V (FLNR_ID 35 – 600 A);

300 V (FLSR_ID)

Interrupting Ratings

AC: 200 kA rms symmetrical

300 kA rms symmetrical

(Littelfuse self-certified)

DC: 20 kA

Ampere Range

1

/

10

– 600 A

Approvals

Standard 248-12, Class RK5

UL Listed (File: E81895)

CSA Certified (File: LR29862)

Federal Specification WF-1814

(QPL- W-F-1814)

Web Resources

Download TC Curves, CAD drawings and other technical
information: littelfuse.com/flsr

littelfuse.com/flnr

ampERE RatINgs

1

/

10

6

/

10

1

8

/

10

4

8

30

80

225

1

/

8

*

8

/

10

2

4

1

/

2

9

35

90

250

15

/

100

1

2

1

/

4

5

10

40

100

300

2

/

10

1

1

/

8

2

1

/

2

5

6

/

10

12

45

110

350

1

/

4

1

1

/

4

2

8

/

10

6

15

50

125

400

3

/

10

1

4

/

10

3

6

1

/

4

17

1

/

2

60

150

450

4

/

10

1

1

/

2

3

2

/

10

7

20

70

175

500

1

/

2

1

6

/

10

3

1

/

2

7

1

/

2

25

75

**

200

600

*FLNR only. †FLNR, FLSR, FLSR_ID only. **FLNR, FLSR, FLSR_ID only
Note: For

1

/

10

– 30A 250 volt fuses, order non-indicating FLNR series fuses.

Recommended Fuse Holders

LFR60 Series • LFR25 Series

Dimensions

Please refer to the Class R dimensions page 2.

Peak Let-Thru Curve (600 V)

Note: For more information, see Peak Let-Thru Table

Ordering Information

typE

Volt

sERIEs Amp Catalog

NUmbER

oRDERINg

NUmbER

NON-INDICAtING

600

FLSR

15

FLSR015

FLSR015.t

INDICAtING

600

FLSR_ID

15

FLSR015ID

FLSR015.tXID

NON-INDICAtING

250

FLNR

60

FLNR060

FLNR060.t

INDICAtING

250

FLNR_ID

60

FLNR060ID FLNR060.tXID

QPL

FLSR_ID

Advertising