Generator & Single-Function Protection–3-Phase Short-Circuit

T2300 SerieS

3-Phase Short-Circuit Relay

Description

The T2300 3 Phase Short-Circuit Relay is designed for

protection of generators, power transmissions and

consumer’s supply against short circuit. The T2300 reacts on

a definite delay versus current level.
The T2300 detects the highest of the 3 input currents and,

if this exceeds the preset level (1.0 - 4.0 x I

N

), the pick-up

LED will indicate and the delay timer will be started. After

the preset time (0.1-1.0 sec.) has expired, the normally

energized output relay will de-energize and the relay LED will

be activated, provided that the current level was exceeded

for the entire delay time. The T2300 has a normally energized

output relay.

Specifications

Trip Level

1.0-4.0 x I

N

Delay

0.1-1.0 sec.

Max. Voltage

660 V

Voltage Range

60-110%

Consumption

Voltage 5 VA at U

N

Current 0.3 VA at I

N

Continuous Current

2 x I

N

Frequency Range

45-400 Hz

Output Relay

Normally de-energized, latching, resetable

Contact Rating

AC: 400 V, 5 A, 2000 VA

DC: 150 V, 5 A, 150 W

Overall Accuracy

±5%

Repeatability

±1%

Operating Temperature –20°C to + 70°C

Dielectric Test

2500 V, 50 Hz

EMC

CE according to EN50081-1, EN50082-1,

EN50081-2, EN50082-2

Approvals

Certified by major marine classification societies

Burn-in

50 hours before final test

Enclosure Material

Polycarbonate. Flame retardant

Weight

0.5 kg

Dimensions H

70 mm (2.76”); W 100 mm (3.94”);

D 115 mm (4.52”)

Installation

35 mm DIN rail or 4 mm (

3

/

16

”) screws

OrderinG

number

TerminalS

i

n

FunCTiOn

1-3

2-3

T2300.0100

230 V

5 A

T2300.0020

450 V

400 V 5 A

T2300.0030

24 Vdc

5 A

T2300.0040

24 Vdc

1 A

T2300.0050

450 V

400 V 5 A Normally de-energized output

T2300.0060

480 V

415 V 5 A

T2300.0070

230 V

1 A

Ordering Information

Simplified Circuit Diagram

Features & Benefits

SUPPLY

I

1

U

I

2

I

3

2
3

11

12

13

14
15
16

1

10

9

8

7

6

5

L

1

L

2

L

3

SHORT CIRCUIT

T2300

(3-Phase Short-Circuit Relay)

Other supply voltages and combinations are available on request.

FeaTureS

beneFiTS

Accepts high supply

voltage variation

Ensures correct operation in spite of voltage

supply fluctuations (fulfills marine class

requirement)

Visual indication of

power, pick-up, and

output trip

Provides quick and concise status information

Direct line-line or line-

neutral voltage supply

(up to 690 Vac)

Simplifies design and installation.

No need for PTs.

Built-in capacitor

cack-up supply

Ensures correct operation in spite of drop in

the supply voltage

Galvanic isolated inputs

Protects the unit against high AC voltage and

currents from the installation including spikes

DIN-rail or screw-mount

& adjustment by

potentiometers

Easy installation

Rev 4-A-050213