Littelfuse SE-703 Series User Manual

Se-703 series, Protection relays & controls, Earth-leakage monitor specifications

Advertising
background image

Protection Relays & Controls

© 2013 Littelfuse Protection Relays & Controls

Littelfuse.com/se-703

Ground-Fault Protection–Grounded Systems

Description

The SE-703 is a microprocessor-based ground-fault relay for resistance-

and solidly-earthed systems. It offers sensitive ground-fault detection as

low as 25 mA and can be used on systems with significant harmonic

content. The SE-703 provides feeder-level protection or individual-load

protection. The output contacts can be connected for use in protective

tripping circuits or in alarm indication circuits. The analog output can be

used with a PLC or a meter. The SE-703 is specifically designed to be

Australian AS/NZS 2081 compliant.

SE-703 SEriES

Earth-Leakage Monitor

Specifications

IEEE Device Numbers

Ground fault (50G/N, 51G/N)

Input Voltage

See ordering information

Dimensions

H 75 mm (3.0"); W 55 mm (2.2"); D 115 mm (4.5")

Trip Level Settings

25-500 mA

Trip Time Settings

50-500 ms

Contact Operating Mode Selectable fail-safe or non-fail-safe

Harmonic Filtering

Standard feature

Test Button

Standard feature

Reset Button

Standard feature

CT-Loop Monitoring

Standard feature

Output Contacts

Isolated Form A and Form B

Approvals

CSA certified, UL Listed (E340889), CE (European Union),

C-Tick (Australian)

Compliance

AS/NZS 2081:2002

Analog Output

0-5 V

Conformally coated

Consult factory

Warranty

5 years

Mounting

DIN, Surface (standard)

Panel (with PMA-55 or PMA-60 adapter)

OrdErinG numbEr

cOntrOl POwEr

SE-703-OU

120/240 Vac/Vdc

SE-703-OD

12/24 Vdc

SE-703-OT

48 Vdc

SE-703-O3

24 Vac

Ordering Information

Simplified Circuit Diagram

FEaturES

bEnEFitS

Adjustable pickup

(25 - 500 mA)

Adjustable trip setting provides a wide range of low-level

protection and system coordination

Adjustable time delay

(50 - 500 ms)

Adjustable trip delay allows quick protection and system

coordination

Output contacts

Form A and Form B ground-fault output contacts for

operation of separate annunciation and trip circuits

Analog output

(0 - 5 V)

Allows for connecting an optional meter (PGA-0500) or

control system

CT-Loop monitoring

Alarms when CT is not connected

Selectable contact

operating mode

Selectable fail-safe or non-fail-safe operating modes

allow connection to shunt or undervoltage breaker coil

Harmonic filtering

Eliminates nuisance tripping

Non-volatile trip

memory

Retains trip state while de-energized to simplify

troubleshooting

Microprocessor based

No calibration required, saves maintenance cost

Universal

power supply

Allows operation in application where one side of PT is

faulted, provides flexibility for numerous applications

Features & Benefits

Note: For optional conformal coating please consult factory.

accESSOriES

rEquirEmEnt

EFCT Series

Required

PGA-0500

Optional

PMA-55, PMA-60

Optional

SE-EFVC Voltage Clamp

Optional

Accessories

EFCT Series Ground-Fault Current Transformer

Required zero-sequence current transformer

specifically designed for low-level detection.

PGA-0500 Analog % Current Meter

Optional panel-mounted analog meter displays ground-

fault current as a percentage of the set-point or 5 A.

A

A

B

CT

L2

L1

GROUNDED

SUPPLY

SE-703 SERIES

(Earth-Leakage Monitor)

A

B

C

Rev: 4-A-050213

Based on Manual Rev 10-A-042313