Littelfuse 215SP Series User Manual

Axial lead & cartridge fuses, 5×20 mm > time-lag (slo-blo, 215sp series

Advertising
background image

© 2013 Littelfuse, Inc.

Specifications are subject to change without notice.
Revised: 12/19/13

Axial Lead & Cartridge Fuses

5×20 mm > Time-Lag (Slo-Blo

®

) > 215SP Series

215SP Series, 5×20 mm, Time-Lag Fuse (Slo-Blo

®

)

Agency Approvals

Agency

Agency File Number

Ampere Range

PS

E

Certificate No.

Leaded
NBK080205-

E10480B
NBK250702-

E10480F

1A – 5A

6.3A – 10A

Certificate No.

CQC10012041490

1A – 6.3A

Certificate No.

SU05001-2011B

SU05001-10001

SU05001-10002

1A – 2.5A

3.15A – 6.3A

8A

Recognised

File No.

Guide No.

E10480

JDYX2

1A – 10A

File No.

Acc. Class No.

029862

LR1422-30

1A – 10A

Licence. No.

40013521

1 – 8A

1A – 10A

Features

Electrical Characteristics for Series

% of Ampere

Rating

Ampere Rating

Opening Time

210%

1A - 3.15A

30 minutes, Maximum

4A - 6.3A

30 minutes, Maximum

8A - 10A

30 minutes, Maximum

275%

1A - 3.15A

.75 sec. Min.; 80 secs. Max.

4A - 6.3A

.75 sec. Min.; 80 secs. Max.

8A - 10A

.75 sec. Min.; 80 secs. Max.

400%

1A - 3.15A

.095 sec. Min.; 5 secs. Max.

4A - 6.3A

.150 sec. Min.; 5 secs. Max.

8A - 10A

.150 sec. Min.; 5 secs. Max.

1000%

1A - 3.15A

.010 sec. Min.; .150 secs. Max.

4A - 6.3A

.010 sec. Min.; .150 secs. Max.

8A - 10A

.010 sec. Min.; .150 secs. Max.

Applications

I

2

t test at 10x rated current

5×20mm Time-Lag surge withstanding ceramic body
cartridge fuse designed to IEC specification

• Designed to International

(IEC) Standards for use

globally

• RoHS compliant and Pb-

free

• Meets the IEC 60127-2,

Sheet 5 specification for

Time-Lag Fuses

Used as supplementary protection in appliance or
utilization equipment to provide individual protection for
components or internal circuits.

PS

E

Description

Electrical Characteristic Specifications by Item

Amp

Code

Amp

Rating

Voltage

Rating

Interrupting

Rating

Nominal

Resistance

Cold Ohms

(Ohms)

Nominal

melting I

2

t

(A

2

sec)

maximum

Voltage Drop at

Rated Current

(mV)

maximum

power

Dissapation at

1.5ln

(W)

Agency Approvals

PS

E

001

1

250

1500 A @

250 VAC

0.1515

1.52000

350

2.5

x

x

x

x

x

x

x

1.25

1.25

250

0.1074

3.20000

300

2.5

x

x

x

x

x

x

x

01.6

1.6

250

0.0707

6.83000

200

2.5

x

x

x

x

x

x

x

002

2

250

0.0566

11.68000

190

2.5

x

x

x

x

x

x

x

02.5

2.5

250

0.0386

22.29000

180

2.5

x

x

x

x

x

x

x

3.15

3.15

250

0.0283

43.25500

140

4

x

x

x

x

x

x

x

004

4

250

0.0185

46.96000

100

4

x

x

x

x

x

x

x

005

5

250

0.0153

66.09500

100

4

x

x

x

x

x

x

x

06.3

6.3

250

0.0108

128.75000

100

4

x

x

x

x

x

x

x

008

8

250

0.0092

209.88000

100

4

x

x

x

x

x

x

010

10

250

0.0066

333.56500

100

4

x

x

x

x

Advertising