Ocean Optics Sensors for Real-Time Analysis User Manual

Sensors for real-time analysis, Neofox phase measurement system, Advanced sampling options and detection technology

Advertising
background image

www.oceanoptics.com | [email protected] | +1 727-733-2447

Sensors for Real-Time Analysis

advanced sampling options and detection technology

Ocean Optics optical sensors provide a viable alternative to traditional chemical sensing
devices and consist of transducer materials applied to the tips of optical fibers or to
substrates such as patches or cuvettes. These indicator materials change optical properties
in response to specific analytes in their immediate environment, with formulations
available for a variety of oxygen and pH sensing needs.

Thanks to our developments in sensor detection technology and sampling options, you
can enjoy lower system prices and greater application versatility than ever before.

NeoFox Interface

NeoFox Phase Measurement System

A new option for the detection part of our fluorescence-based optical sensor systems helps reduce costs, improve
system stability and make calibration easier for most oxygen sensing setups. NeoFox is a benchtop device for
measurement of fluorescence lifetime, phase and intensity, and is especially useful for applications where sensitivity to
drift and system stability are important. What's more, NeoFox is about half of the cost of our previous phase-
measurement system, and includes a self-calibration feature for improved electronic stability.

Complete O2 Sensing Systems including NeoFox, general purpose

probe, software and accessories.

Starting under $3,000

System
Specifications

FOXY Formulation

FOSPOR Formulation

HIOXY Formulation

(general-purpose coating)

(high-sensitivity for low levels
of O2)

(for hydrocarbon
environments)

O2% range:

0-20%

0-<1%

0-20.9% at 1 ATM

DO range (ppm):

0-10 ppm

0-0.5 ppm

0-8 ppm

-20-+80 ºC for probes

-20-+80 ºC for probes

0-60 ºC

0-60 ºC for patches

0-60 ºC for patches

NA

O2 resolution:

100-500 ppm

10 ppm

100-500 ppm

DO resolution:

4-20 ppb at room temp.

0.4-2 ppb at room temp.

4-20 ppb at room temp.

O2 accuracy:

5% of reading

5% of reading

5% of reading

DO accuracy:

5% of reading

5% of reading

5% of reading

Min. detectable level:

100-500 ppm

10-100 ppm

100-500 ppm

< 1 second in gas

< 1 second in gas

< 1 second in gas

~30 seconds with overcoating
in gas

~30 seconds with overcoating
in gas

~45 seconds in pure water

~45 seconds in pure water

~45 seconds in pure water

Response time:

Temperature range:

Advertising