B.3.31. at+pass=$string, B.3.32. at+chpass=$string, B.3.33. atsnn – SENA Parani-ESD1000 User Manual

Page 49: B.3.34. atsnn=mm

Advertising
background image

49

B.3.31. AT+PASS=$string

Response

Remote Configuration Enabled

Purpose

Input password in remote configuration mode.

Parameters

$string= Password (Default=”0000”)

Description

Input password for authentication in remote configuration mode.

Example

AT+PASS=1234

B.3.32. AT+CHPASS=$string

Response

 OK

Purpose

Change password used in remote configuration mode.

Parameters

$string= New password

Description

Change password used in remote configuration mode. Password length is up to 8.

Example

AT+CHPASS=12345678

B.3.33. ATSnn?

Response

 value
 OK

Purpose

Display a given S-register

Parameters

nn= Address of S-register

Description

A specific S-register will be displayed.

B.3.34. ATSnn=mm

Response

 OK

Purpose

Change S-register value

Parameters

nn= Address of S-register
mm= New value of S-register

Description

Some S-registers are optimized for the overall performance and protected and cannot be
changed. When users try to change these S-registers, response is ‘ERROR’.
For details of S-register, refer Appendix. B.

Example

ATS10=0