3. Wrap a 3” (7.62 cm)

long piece of PTFE

tape to the right

around the male

threads of the fittings.

Wrap tightly so that

it conforms to the

threads of the fitting

and overlaps about

1/2”. (Figure 3)

4. Screw one fitting into

the filter outlet (top)

and the other fitting

into the filter inlet

(side). Tighten both

fittings with a wrench.

Do not overtighten.

(Figure 4)

5. Measure down from

the centerline of the

filter inlet about 3”

and marke the tube.

From this mark, mea-

sure up 8” and mark

the tube. This is the

section of the tube to

be removed. If neces-

sary, because of tight

quarters, additional

tube can be cut away.

(Figure 5)

6. Cut the cold water

tube. Place a pan

under tube to catch

any water that may be

present. (Figure 6)

7. Two compression

fittings are required

for the tube ends.

Check the tube size.

Use 5/8” x 3/8”, 3/8”

x 3/8” or 1/2” x 3/8”

compression fittings

as required. Slip nut

and ferrule on water

tubing as shown and

fasten fittings in place.

(Figure 7)

IMPORTANT INSTALLATION INSTRUCTIONS (Continued)

Figure 8

Figure 9

CAUTION

• Install on

COLD

water lines only.

Figure 10

Figure 11

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

8. Cut two lengths of

3/8” soft copper

tubing and bend to

shape as shown.

Bend tubing to form

gentle curves rather

than sharp bends.

(Figure 8)

9. Connect both pieces

of tubing to filter and

water tube as shown

with compression

fittings. Do not over-

tighten nuts.

(Figure 9)

10. Remove housing by

grasping with both

hands and turning

to the left. A wrench

may be used on the

square lug at the bot-

tom of the housing if

necessary.

(Figure 10)

11. Install cartridge by

threading into head

about 5-6 revolutions.

Do not overtighten.

Lubricate o-ring

with a thin film of a

silicone based lubri-

cant and put it back

in housing groove.

Thread the housing

back on the head and

hand tighten. Using of

wrench to tighten the

housing may damage

housing and result in

water leakage.

(Figure 11)

Do not crimp copper
tubing.

IMPORTANT NOTE

12.Open the cold water faucet to expel any trapped air. Open

the shut-off valve to allow water to enter the filter. If any

leaks occur, close the shut-off valve and open the faucet

to relieve the pressure, then gently tighten the fitting that

is leaking. Flush 10 gallons through system before use

(approximately 5 to 7.5 minutes).

Compression

Fittings

Cold Water Line

Shut Off

Valve

Cold Water Line

Section of Tubing

Removed

Nut
Ferrule

Compression Fittings

Ferrule
Nut

Cartridge

O-Ring

Outlet

Inlet

Completed Connections