Caution drain connection installation (figure 5) – Aqua-Pure AP-RO5500 User Manual

Page 18

Advertising
background image

Installation, Operation and Maintenance Manual

Using Push-In Fittings (Figure 4)

This product is equipped with user-friendly “Push In” connectors. Proper use of the connectors is shown in the dia-
grams. It is most important that the tubing selected for use with the connectors be of high quality, exact size and round-
ness, and with no surface nicks or scratches. If it is necessary to cut the tubing, use a plastic tubing cutter or sharp
razor knife. Make a clean square cut. Should a leak occur at a Push In connector, the cause is usually defective tubing.

To fi x: 1. Relieve pressure.

2. Release tubing.

3. Cut off at least 1/4” from end.

4. Reattach tubing.

5. Confi rm connection is leak-free.

17

To Release Tubing

Push in grey collet to release tubing. With collet
held, pull tubing straight out.

Collet

Backstop

To Attach Tubing

Push tubing in as far as it will go. Tubing must be in-
serted past o-ring and hit backstop. Pull tube to ensure
it is secured.

CAUTION

To reduce the risk associated with property damage due to water leakage:
• Ensure all tubing and fi ttings are secure and free of leaks.

To reduce the risk associated with property damage due to water leakage:
Ensure all tubing and fi ttings are secure and free of leaks.
Do not install unit if collet is missing. Contact 3M PI if collets are missing from any fi ttings.

CAUTION

Drain Connection Installation (Figure 5)

Garbage
Disposal

NEVER mount here

Mount drain saddle at

either location

Hole should be

located on top

of the pipe

Drain saddle elbow

Drain saddles

Drain Connection

(horizontal example)

Advertising